K N Interstate Gas Transmission Co.

Second Revised Volume No. 1-B

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/1994, Docket: RP94-397-000, Status: Effective

First Revised Sheet No. 15 First Revised Sheet No. 15 : Superseded

Superseding: Original Sheet No. 15

GENERAL TERMS AND CONDITIONS FOR SERVICES - continued

 

 

5.2 The volume of gas delivered through each Point of Delivery and

Receipt shall be corrected to a base temperature of sixty (60)

degrees Fahrenheit by using:

 

a. The arithmetic average of the hourly temperatures recorded by

a properly installed continuously operated recording

thermometer, or

 

b. A meter containing a temperature operated device, hereinafter

referred to as a temperature compensated meter, through the

operation of which the meter correctly registers the volume,

corrected to sixty (60) degrees Fahrenheit, or

 

c. An assumed temperature of the gas flowing through the meters

of fifty (50) degrees Fahrenheit in the case of any small

volume delivery where Transporter does not elect to install a

recording thermometer or temperature compensated meter;

provided, however, in the event Transporter does not install a

recording thermometer or temperature compensated meter,

Shipper may install a recording thermometer and in such case

the temperature so recorded shall be used in correcting to a

temperature of sixty (60) degrees Fahrenheit.

 

5.3 When orifice meters are used, the specific gravity of the gas

delivered shall be determined by approved methods once a month, or

as frequently as necessary for reasonably accurate determination,

and the specific gravity so obtained shall be used in computing

volumes of gas delivered hereunder.

 

5.4 The components for determining the deviation from Boyle's Law, at

the pressure and temperature under which delivered, shall be

determined by tests at intervals of twelve (12) months or at such

shorter interval as is found necessary in practice and the

correction factor so determined using American Gas Association

"Report Number Eight" or American Gas Association "Project NX-19"

shall be used in the computation of deliveries until the next test.