Valero Interstate Transmission Company
First Revised Volume No. 2
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/01/1991, Docket: GT91- 42-000, Status: Effective
Original Sheet No. 31 Original Sheet No. 31 : Superseded
(f) Contain a gross heating value of at least nine hundred seventy-
five (975) Btu per cubic foot, saturated with water vapor at a temperature
of sixty (60) degrees Fahrenheit and at an absolute pressure equivalent to
thirty (30) inches of mercury at thirty-two (32) degrees Fahrenheit;
(g) Have a temperature of not more than one hundred twenty (120)
degrees Fahrenheit, nor less than forty (40) degrees Fahrenheit, when
delivered to Buyer; and
(h) Contain not more than seven (7) pounds of water per one
thousand (1,000) Mcf.
2. Buyer shall have the right to be represented and to participate in
all tests of gas delivered hereunder and to inspect any equipment used in
determining the nature or quality of the gas.
ARTICLE V
POINT OF DELIVERY AND PRESSURE
1. The Point of Delivery for all gas delivered hereunder shall be at
the existing measurement facilities at the Falfurrias Measuring Station,
Vitco to VT, L.P. (832-063), Jim Wells County, Texas, at which point
Interstate will deliver the gas to Valero Transmission, L.P. for the
account of the Buyer. Title to all gas delivered hereunder shall pass at
said Point of Delivery.
2. Interstate shall be in exclusive control and possession of the gas
deliverable hereunder, and responsible for any injury or damage caused
thereby, until such gas is delivered to Buyer, or Buyer's designated agent
for account of Buyer, at the above described point.
3. Interstate shall deliver gas at pressures at said Point of Delivery
sufficient to enter the facilities of Valero Transmission, L.P. at such
Delivery Point, but not in excess of one thousand thirty-five (1,035) psig.