Stingray Pipeline Company

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 10/01/2002, Docket: RP02-469-000, Status: Effective

Third Revised Sheet No. 119A Third Revised Sheet No. 119A : Effective

Superseding: Sub Second Revised Sheet No. 119A

GENERAL TERMS AND CONDITIONS

 

(d) The standard quantity for nominations,

confirmation and scheduling is dekatherms per

gas day in the United States, gigajoules per

gas day in Canada and gigacalories per gas day

in Mexico. (For reference, 1 dekatherm =

1,000,000 Btus; 1 gigajoule = 1,000,000,000

joules; and 1 gigacalorie = 1,000,000,000

calories.) For commercial purposes, the

standard conversion factor between dekatherms

and gigajoules is 1.055056 gigajoules per

dekatherm and between dekatherms and

gigacalories is 0.251996 gigacalories per

dekatherm. The standard Btu is the

International Btu, which is also called the Btu

(IT); the standard joule is the joule specified

in the SI system of units. The International

Btu is specified for use in the gas measurement

standards of the American Gas Association, the

American Petroleum Institute, the Gas

Processors Association and the American Society

for Testing Materials. For non-commercial

purposes, these associations note that the

exact conversion factor is 1.05505585262

Gigajoules per Dekatherm.

 

6.2 STANDARD NOMINATION CYCLES

 

Stingray supports the following standard nomination

cycles:

 

(a) The Timely Nomination Cycle: 11:30 a.m. for

nominations leaving control of the nomination

party; 11:45 a.m. for receipt of nominations by

Stingray (including from Title Transfer

Tracking Service Providers (TTTSPs); noon to

send Quick Response; 3:30 p.m. for receipt of

completed confirmations by Stingray from

upstream and downstream connected parties; 4:30

p.m. for receipt of scheduled quantities by

shipper and point operator (central clock time

on the day prior to flow).

 

(b) The Evening Nomination Cycle: 6:00 p.m. for

nominations leaving control of the nominating

party; 6:15 p.m. for receipt of nominations by

Stingray (including from TTTSPs);6:30 p.m. to

send Quick Response; 9:00 p.m. for receipt of

completed confirmations by Stingray from

upstream and downstream connected parties;

10:00 p.m. for Stingray to provide scheduled

quantities to affected shippers and point

operators, and to provide scheduled quantities

to bumped parties (notice to bumped parties),

(central clock time on the day prior to flow).

 

Scheduled quantities resulting from an Evening

Nomination that does not cause another Service

Requester on Stingray to receive notice that it

is being bumped should be effective at 9:00

a.m. on the gas Day; and when an Evening

Nomination causes another Service Requester on

Stingray to receive notice that it is being

bumped, the scheduled quantities should be

effective at 9:00 a.m. on the gas Day.