U-T Offshore System, L.L.C.

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/1993, Docket: RS92- 88-006, Status: Effective

Original Sheet No. 44 Original Sheet No. 44 : Superseded

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

 

(b) Shall not contain more than one grain of hydrogen sulphide per 100 cubic feet of Gas, as

determined by methods prescribed in Standards of Gas Service, Circular of the National

Bureau of Standards, No. 405, page 134 (1934 Edition), and shall be considered free from

hydrogen sulphide if a strip of white filter paper, moistened with a solution containing

five (5) percent by weight of lead acetate, is not distinctly darker than a second paper

freshly moistened with the same solution, after the first paper has been exposed to the

Gas for 1« minutes in an apparatus of approved form, through which the Gas is flowing at

the rate of approximately five cubic feet per hour, the Gas from the jet not impinging

directly upon the test paper; or the hydrogen sulphide content may be determined by an

instrument of approved type and by approved methods when mutually agreeable to the

Parties;

 

(c) Shall not contain more than 20 grains of total sulphur (including the sulphur in any

hydrogen sulphide and mercaptans) per 100 cubic feet;

 

(d) Shall not at any time have an oxygen content in excess of one percent by volume, and the

Parties hereto shall make every reasonable effort to keep the Gas free of oxygen;

 

(e) Shall not contain more than seven (7) pounds of water per million cubic feet of Gas

delivered;

 

(f) Shall not contain more than three (3) percent by volume of carbon dioxide; provided,

however, that Shipper will in any event inject corrosion inhibitor in accordance with

standards established by U-TOS;

 

(g) Shall be delivered at a temperature not in excess of 120 degrees Fahrenheit or less than

65 degrees Fahrenheit;

 

(h) Shall not contain more than three (3) percent by volume of nitrogen.

 

4.4 Failure to Meet Receipt Specifications. Should any Gas tendered for delivery to U-TOS

hereunder fail at any time to conform to any of the specifications of this Article, U-TOS shall

notify Shipper of any such failure, and U-TOS may at its option suspend all or a portion of the

receipt of any such Gas, and U-TOS shall be relieved of its obligations hereunder for the

duration of such time as the Gas does not meet such specifications.

 

4.5 Failure to Meet Delivery Specifications. Should the Gas tendered for delivery by U-TOS

hereunder fail at any time to conform to any of the specifications of this Article, U-TOS shall

make a diligent effort to correct such failure by treatment not prohibited by these General

Terms and Conditions and consistent with prudent operations and by means which are economically

feasible in U-TOS' opinion so as to deliver Gas conforming to the above specifications.

 

4.6 Commingling. It is recognized that Gas delivered by Shipper will be commingled with the Gas of

others in the System. Accordingly, the Gas of Shipper shall be subject to such changes in Btu

value as may result from such commingling. Equivalent volumes, as referenced in the

Transportation Agreement, and as defined in Article IV, Section 4.1, 4.2 and 4.3 of the Gas

Allocation Agreement, will be redelivered for the account of Shipper.