2.6 Complaints

----------

 

In the event that a Shipper or potential Shipper has a complaint relative to

service under this Third Revised Volume No. 1, the Shipper shall:

 

(a) Provide a written description of the complaint, including the

identification of the transportation request, and send it to:

 

U-T Offshore System

c/o ANR Pipeline Company, Operator

500 Renaissance Center

Detroit, Michigan 48243

 

Attention: Manager, Business Operations

 

(b) U-TOS will respond to any such complaint verbally within 48 hours after

receipt of the complaint. In the initial response, U-TOS will acknowledge

receipt of the complaint and request any additional information that is

needed to process the complaint. Within thirty days from the day of

receipt of a written complaint, U-TOS will respond to the complaint in

writing advising Shipper of the disposition of the complaint.

 

2.7 Information

-----------

 

Any person may request information on the pricing or other terms of

transportation service and/or capacity availability by contacting U-TOS at the

following:

 

U-T Offshore System

c/o ANR Pipeline Company, Operator

500 Renaissance Center

Detroit, Michigan 48243

 

Attention: Manager, Business Operations

 

Such information may also be available to parties having authorized access to

U-TOS' Electronic Delivery Mechanism, as further described in Section 20 of

these General Terms and Conditions.

 

3. MEASUREMENT

 

3.1 Unit of Measurement and Metering Base. The volumetric measurement base shall

be 1 cubic foot of Gas at a pressure base of 14.73 pounds per square inch

absolute, a temperature base of 60 degrees Fahrenheit (on a dry basis).

 

3.2 The unit of gas received and delivered by Transporter shall be 1 Dth. The

number of Dth shall be determined by multiplying the number of standard cubic

feet of gas measured on the measurement basis described in this section, by the

total Heating Value of such gas in Btu per standard cubic foot as defined in

Section 4.1 below, and by dividing the product by 1 million (1,000,000). For

reporting purposes, Btu conversion factors should be reported to not less than

3 decimal places and Pressure Base conversion factors should be reported to not

less than 6 decimal places. For calculation purposes, not less than 6 decimal

places should be used for both conversion factors.