Pinnacle Pipeline Company
ORIGINAL VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/08/2003, Docket: RP04-102-001, Status: Effective
Original Sheet No. 111 Original Sheet No. 111 : Effective
(b) By comparing deliveries made during the
preceding period under similar delivery
conditions when the equipment was
registering accurately.
3.7 Measurement of Moisture
Transporter may install on-line at the Delivery
Point(s) the most accurate and reliable
technology currently available at reasonable cost
to continuously monitor the moisture content of
the gas being delivered by Transporter. Moisture
content monitoring equipment installed by
Transporter, if any, will have the capacity for
an alarm, which may be installed by Shipper, to
inform Shipper whenever the moisture content of
the gas being delivered to Shipper exceeds the
maximum designated by the Tariff specifications
referenced in Section 2.1. If Transporter does
not install moisture monitoring equipment as
permitted by this section, Shipper's moisture
monitoring equipment located on-line at the
Delivery Point(s) will be used to determine the
moisture content of gas being delivered by
Transporter, if that equipment has been properly
installed and maintained and is registering
correctly. Shipper will promptly notify
Transporter if the moisture content of gas being
delivered to Shipper exceeds the maximum
designated by the Tariff specifications
referenced in Section 2.1.
3.8 Measurement of Gross Calorific Heating Value,
Carbon Dioxide, Oxygen, Nitrogen and Hydrogen
Sulfide
Transporter's gas chromatograph installed at the
Receipt Point shall be used to measure the gross
calorific heating value, carbon dioxide, oxygen
and nitrogen levels in the gas stream. The
standard for calculation of gross calorific
heating value, specific gravity and
compressibility of gas mixtures from
compositional analysis shall be Gas Processors
Association Standard No. 2172-84, as amended or
supplemented from time to time. If Shipper
accepts delivery of any gas that contains
moisture in excess of the limit for dry gas