Pinnacle Pipeline Company
ORIGINAL VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/08/2003, Docket: RP04-102-001, Status: Effective
Original Sheet No. 109 Original Sheet No. 109 : Effective
promptly of such deficiency and follow
notification in writing. If gas delivered to the
Delivery Point(s) fails to conform to the quality
specifications, Shipper shall notify Transporter
promptly of such deficiency and follow
notification in writing. In both instances, the
deficiency shall be remedied within a reasonable
period of time. Neither Transporter nor Shipper
shall be required to receive gas that fails to
conform to the quality specifications.
3. MEASUREMENT
3.1 Measurement Facilities
Transporter, at its sole cost and expense, shall
provide for the continued operation and
maintenance of gas measuring facilities to be
located at the Receipt Point and Delivery Points.
Such facilities shall be constructed and gas
volumes shall be measured by (1) orifice metering
tubes at the Delivery Point(s) installed in
compliance with the requirements prescribed in
Gas Measurement/Committee Report No. 3 of the
American Gas Association approved standards
measurement, including the appendix thereto, and
any subsequent revision thereof acceptable to
Shipper and Transporter or their designees and
(2) ultrasonic meters at the Receipt Point
installed in compliance with the requirements
prescribed in Gas Measurement/Committee Report
No. 9 of the American Gas Association approved
standards measurement, including the appendix
thereto, and any subsequent revision thereof
acceptable to Shipper and Transporter or their
designees.
3.2 Check Metering Equipment - Shipper shall have the
right, at its sole option and expense, to install
and operate check metering equipment downstream
of the Receipt Point and the Delivery Points.
3.3 Gas Measurement and Equipment - Reading,
calibration and adjustment of each party's meters
and related equipment shall be performed solely
by that party. Each party, however, shall
provide the other with seven (7) Days prior
written notice of all reading, calibration and