Pinnacle Pipeline Company
ORIGINAL VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/08/2003, Docket: RP04-102-001, Status: Effective
Original Sheet No. 108 Original Sheet No. 108 : Effective
51. "Year" means a period of 365 consecutive days,
except that any year which contains the date
February 29 shall consist of 366 consecutive
days.
2. QUALITY OF GAS
2.1 Gas Quality Specifications: All gas tendered at
the Receipt Point and delivered to the Delivery
Points hereunder shall be of merchantable
quality, and shall conform to the quality
specifications and requirements as provided
below:
(a) The gas shall be commercially free from
objectionable odors, solid matter, +dust,
gums and gum-forming constituents, or any
other substance which might interfere with
the merchantability of the gas, or cause
injury to or interference with proper
operation of the lines, meters, regulators,
or other appliances through which it flows.
(b) Oxygen - less than or equal to 0.2% by
volume.
(c) Hydrogen sulfide - less than or equal to
1/4 grain/Ccf.
(d) Total Sulphur - less than or equal to 20
grains/Ccf.
(e) Carbon Dioxide - less than or equal to 2.0%
by volume.
(f) Water - less than or equal to 6
pounds/MMcf.
(g) Heating Value - greater than or equal to
950 Btu/Cubic Foot.
(h) The temperature shall be less than or equal
to 120 degrees Fahrenheit.
If at any time, gas tendered to Transporter at
the Receipt Point fails to conform to the quality
specifications, Shipper shall notify Transporter