Pinnacle Pipeline Company

ORIGINAL VOLUME NO. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 10/08/2003, Docket: RP04-102-001, Status: Effective

Original Sheet No. 108 Original Sheet No. 108 : Effective

 

 

51. "Year" means a period of 365 consecutive days,

except that any year which contains the date

February 29 shall consist of 366 consecutive

days.

 

2. QUALITY OF GAS

 

2.1 Gas Quality Specifications: All gas tendered at

the Receipt Point and delivered to the Delivery

Points hereunder shall be of merchantable

quality, and shall conform to the quality

specifications and requirements as provided

below:

 

(a) The gas shall be commercially free from

objectionable odors, solid matter, +dust,

gums and gum-forming constituents, or any

other substance which might interfere with

the merchantability of the gas, or cause

injury to or interference with proper

operation of the lines, meters, regulators,

or other appliances through which it flows.

 

(b) Oxygen - less than or equal to 0.2% by

volume.

 

(c) Hydrogen sulfide - less than or equal to

1/4 grain/Ccf.

 

(d) Total Sulphur - less than or equal to 20

grains/Ccf.

 

(e) Carbon Dioxide - less than or equal to 2.0%

by volume.

 

(f) Water - less than or equal to 6

pounds/MMcf.

 

(g) Heating Value - greater than or equal to

950 Btu/Cubic Foot.

 

(h) The temperature shall be less than or equal

to 120 degrees Fahrenheit.

 

If at any time, gas tendered to Transporter at

the Receipt Point fails to conform to the quality

specifications, Shipper shall notify Transporter