TransColorado Gas Transmission Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2003, Docket: RP00-459-002, Status: Effective
Original Sheet No. 257B Original Sheet No. 257B : Superseded
GENERAL TERMS AND CONDITIONS
20. SYSTEM OPERATION - (Continued)
(vi) Reconcile transportation imbalances; and/or
(vii) Such other voluntary action as would tend to
alleviate or forestall the situation.
(b) TransColorado may also take actions within its control
that might tend to alleviate or forestall the situation. Such actions may
include the following:
(i) Advise any Shipper which is not maintaining
receipts and deliveries in balance that such imbalances must not continue;
(ii) Curtail or require adjustments or supply shifts in
IT service; and/or
(iii) Take such other actions as are within
TransColorado's control and discretion to alleviate or forestall the
situation.
20.5 Critical Time Notice.
(a) A Critical Time may be declared (1) when the total
physical receipts to all or a portion of the system are approaching or
expected to approach a level that is in excess of the total physical
deliveries (2) when the total physical deliveries from all or a portion of
the system are approaching or expected to approach, a level that is in
excess of the total physical receipts; (3) when system pressure on one or
more pipeline segments is falling and approaching a level or is expected
to fall and approach a level that is at or below the minimum that
TransColorado considers necessary for system integrity or to fulfill its
firm contractual obligations; (4) when system pressure on one or more
pipeline segments is rising and approaching a level or is expected to
rise and approach a level that is at or above the maximum pressure at
which TransColorado's facilities may be safely operated; or (5) at other
times when TransColorado is unable or anticipates it may not be able to
fulfill its firm contractual obligations or otherwise when necessary to
maintain the overall operational integrity of all or a portion of
TransColorado's system. A Critical Time may not be declared on all or a
portion of the system for the purpose of maintaining interruptible
services on that portion of the system, but interruptible gas may flow at
times or on portions of the system when such flow would not violate any
operational control restrictions or provisions of this Tariff.
TransColorado shall notify Shippers on the DART system as to the reason(s)
why a Critical Time was declared.