Texas Gas Transmission Corporation

First Revised Volume No. 2-A

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/1990, Docket: RP90-192-000, Status: Effective

Original Sheet No. 72 Original Sheet No. 72 : Effective

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

1.21 The term "PVR" is the abbreviation employed to

denote Plant Volume Reduction. The PVR is the

total of the MMBtu's removed and deducted from the

gas stream from the time the gas enters a pro-

cessing plant until it leaves the plant. The

reduction in MMBtu's includes total plant products

removed, pro rata share of plant fuel and other

uses and pro rata share of incidental plant losses.

 

2. Quality

 

2.1 Gas received or delivered hereunder shall:

 

(a) Be merchantable natural gas, commercially free

from dust, solids, gums, gum-forming constitu-

ents, gasoline, water, or any other substance

of any kind which may become separated from

the gas in the course of transportation

through Transporter's or Transporter's agents'

pipeline(s);

 

(b) Not contain more than seven (7) pounds of

water per million standard cubic feet of gas

determined by analytical instrumentation of

standard manufacture for this purpose includ-

ing the Bureau of Mines type dew point(s)

tester;

 

(c) Not contain more than one (1) grain of hydro-

gen sulfide, nor more than twenty (20) grains

of total sulfur, per one hundred (100) stan-

dard cubic feet of gas; and

 

(d) Contain zero percent (0.0%) hydrogen, not more

than one-tenth of one percent (.1%) by volume

of oxygen, nor more than two percent (2%) by

volume of carbon dioxide, nor more than four

and one half percent (4-1/2%) by volume of all