Petal Gas Storage Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 03/15/2002, Docket: CP00- 59-002, Status: Effective
First Revised Sheet No. 119 First Revised Sheet No. 119 : Effective
Superseding: Original Sheet No. 119
GENERAL TERMS AND CONDITIONS (Continued)
shall in all events be of such quality that it shall meet at least the
following specifications:
(a) Be commercially free from objectionable odors, dirt, dust, iron
particles, gums, gum-forming constituents, gasoline, PCB's, and
other solid and/or liquid matter, including but not limited to
water, gas treating chemicals and well completion fluids and
debris, which may become separated from the gas during the
transportation thereof.
(b) Contain not more than one fourth (1/4) of one grain of hydrogen
sulphide per one hundred (100) cubic feet, as determined by the
cadmium sulfate quantitative test, nor more than twenty (20)
grains of total sulphur per one hundred (100) cubic feet.
(c) The gas delivered hereunder shall not contain more than
two-tenths of one percent (0.2%) by volume of oxygen, shall not
contain more than three percent (3%) by volume of carbon
dioxide, shall not contain more than three (3%) by volume of
nitrogen, and shall not contain a combined total of carbon
dioxide and nitrogen components of more than four (4%) by
volume.
(d) Have a heating value of not less than nine hundred and
sixty-seven (967) BTU's per cubic feet and not more than eleven
hundred (1100) BTU's per cubic feet.
(e) Have a temperature of not more than one hundred twenty degrees
Fahrenheit (120 degrees F), nor less than forty degrees
Fahrenheit (40 degrees F).
(f) Have been dehydrated by the tendering party, by any method other
than the use of a calcium chloride as desiccant, for removal of
entrained water in excess of seven (7) pounds of water per
million (1,000,000) cubic feet of gas as determined by dew-point
apparatus approved by the Bureau of Mines or such other apparatus
as may be mutually agreed upon.
8.2 Rejection of Gas. Either party shall be entitled to reject any gas
tendered to it by the other party which does not meet the minimum
specifications of Section 8.1. Acceptance of such gas does not
constitute any waiver of either party's right to refuse to accept
similarly nonconforming gas.