Texas Eastern Transmission Corporation
Sixth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/1993, Docket: RS92- 11-009, Status: Effective
Original Sheet No. 237 Original Sheet No. 237 : Effective
RATE SCHEDULE PTI
(Continued)
to the executed service agreement. In addition, prior to the date service is to
commence under this Rate Schedule, Customer shall prepay Pipeline for such first
month of service, and thereafter, Customer shall continue to pay Pipeline, in
advance, for the service to be received in the next calendar month.
4. MINIMUM COMMODITY BILL
None.
5. SCHEDULING OF RECEIPTS AND DELIVERIES
5.1 Nominations and Scheduling For service under this Rate Schedule
Customer shall give notice to Pipeline in accordance with Section 4 of Pipeline's
General Terms and Conditions not less than fifteen (15) days prior to the
beginning of the applicable Summer Season of the total volume of gas Customer
desires Pipeline to transport under this Rate Schedule during that period.
Customer's nomination may not exceed the sum of Customer's available storage
capacity under Pipeline's storage Rate Schedules and/or if applicable, the total
quantity confirmed by the operator of the third party storage or the intermediate
interconnecting pipeline and/or, if applicable, the former service level under
Rate Schedule ACQ. Pipeline shall allocate capacity available for service under
this Rate Schedule on a pro rata basis based upon the nominated Maximum Daily
Quantity of all nominating Customers who have submitted valid nominations from
and including January 1 to and including March 15. No nomination for that Summer
Season shall be deemed a valid nomination if such nomination is submitted prior
to January 1 of any year. Pipeline shall allocate all remaining capacity
available for service after scheduling those valid nominations received prior to
March 16 under this Rate Schedule on a pro rata basis based upon the nominated
Maximum Daily Quantity of all nominating Customers who have submitted valid
nominations from and including March 16 to and including April 15. Valid
nominations received prior to March 16 shall have priority over valid nominations
received on or after March 16. In the event Pipeline is unable to accept all
valid nominations hereunder which have the same priority, the available PTI
quantities shall be allocated to the nominating Customers who have the same
priority on a pro rata basis based upon the nominated Maximum Daily Quantity of
all nominating Customers who have the same priority. To the extent there are
conflicts between the scheduling provision in this Section 5 and Section 4 of
Pipeline's General Terms and Conditions of Pipeline's FERC Gas Tariff, Section 5
of this Rate Schedule PTI shall control.
5.2 Delivery of Gas Based upon Customer's scheduled quantities pursuant
to such nomination and Section 5.1 of this Rate Schedule, Pipeline shall deliver
for injection into storage and/or as replacement service for former service under
Rate Schedule ACQ, as specified by Customer, such