Texas Eastern Transmission Corporation

Sixth Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 06/01/1993, Docket: RS92- 11-009, Status: Effective

Original Sheet No. 213 Original Sheet No. 213 : Effective

 

RATE SCHEDULE FT-1

(Continued)

 

(2) The Usage-2 Charge Rate, as set forth on Sheet No. 31,

multiplied by that portion of the total quantity of gas

deliveries on any day pursuant to the executed service

agreement, which is in excess of 110% of scheduled service

levels for such day.

 

Usage Charge Rates will be assessed upon the zones of initial receipt and

ultimate delivery of each Dth on Pipeline's system.

 

3.4 In addition to all other charges hereunder, Customers shall pay

Pipeline the applicable Incremental Facility Charge, as set forth on Sheet No.

34, per month per Dth of additional MDQ for which each Customer contracted under

Pipeline's various incremental facility expansions. The additional Dth

applicable for each Customer under each applicable incremental facility expansion

are set forth on Sheet No. 34.

 

3.5 Except as provided in Section 3.6 of this Rate Schedule, in the event

Pipeline fails to deliver on any one day at least 95% of the quantity of gas

requested to be delivered by Pipeline at Point(s) of Delivery which Pipeline is

obligated to deliver on a firm basis at such Point(s) of Delivery on such day up

to the MDQ, the Reservation Charge shall be decreased by the amount of the

Reservation Charge Adjustment (as set forth on Sheet No. 30 of Pipeline's FERC

Gas Tariff, Volume No. 1, as such sheet may be revised, superseded or

supplemented from time to time) multiplied by the quantity of gas not delivered

up to the lesser of the total quantity of gas requested and not delivered, or the

MDQ. Such Reservation Charge Adjustment shall be discounted in the case of an

executed service agreement containing a discounted Reservation Charge Rate in the

same proportion such Reservation Charge Rate is discounted from the maximum

Reservation Charge Rate.

 

3.6 Pipeline shall not be obligated to adjust the Reservation Charge

pursuant to Section 3.5 when Pipeline's failure to deliver on any one day at

least 95% of the quantity of gas requested by Customer to be delivered at

Point(s) of Delivery which gas Pipeline is obligated to deliver on a firm basis

at such Point(s) of Delivery on such day up to the MDQ:

 

(A) is the result of the conduct of Customer or the downstream

operator of the facilities at the Point of Delivery;

 

(B) is the result of Pipeline having operational flow orders in effect

on such day;

 

(C) is the result, during the period from May 1 through November 1 of

any year, of Pipeline performing routine operational maintenance

and repair;

 

(D) is the result of Pipeline performing at anytime repair and

maintenance of its facilities to comply with applicable regulatory

requirements, or