Mid Louisiana Gas Company
Third Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/01/1999, Docket: RP99-268-000, Status: Effective
Third Revised Sheet No. 77 Third Revised Sheet No. 77 : Effective
Superseding: Substitute Second Revised Sheet No. 77
GENERAL TERMS AND CONDITIONS
Each of the following General Terms and Conditions applies to each
Rate Schedule contained in this Third Revised Volume No. 1, unless
otherwise indicated herein or in the applicable Rate Schedule.
1. DEFINITIONS
The following terms, when used herein or in any agreement
incorporating these General Terms and Conditions shall have the
following meaning:
1.1 AGENT. The term "Agent" shall mean any party designated by a
Customer to act on such Customer's behalf under the terms and
conditions of this FERC Gas Tariff.
1.2 BCF. The term "Bcf" shall mean one billion (1,000,000,000)
cubic feet of gas.
1.3 BILLING MONTH or MONTH. The terms "billing month or month"
shall mean the calendar month.
1.4 BRITISH THERMAL UNIT (Btu). The term "Btu" shall mean the
quantity of heat required to raise the temperature of one (1)
pound avoirdupois of pure water from fifty-eight and
five-tenths degrees Fahrenheit (58.5? F.) to fifty-nine and
five-tenths degrees Fahrenheit (59.5? F.) at a constant
pressure of fifteen and twenty-five thousandths (15.025)
pounds per square inch absolute (15.025 psia). Such quantity
shall be reported in compliance with GISB Standard 2.3.9
which is incorporated herein by reference.
1.5 BUSINESS DAY. Business day is defined as Monday through Friday,
excluding Federal Banking Holidays for transactions in the
U.S., and similar holidays occuring in
Canada and Mexico
1.6 COMMISSION or FERC. The terms "Commission" or "FERC" shall
mean the Federal Energy Regulatory Commission or any successor
agency.
1.7 CRITICAL NOTICE. The term "critical notice" shall mean a
notice, in accordance with GISB standards, which pertains
to information on Pipeline conditions that affect scheduling
or adversely affect scheduled gas flow.
1.8 CUBIC FOOT OF GAS. The term "cubic foot of gas" shall mean,
for the purpose of measurement of the gas and for all other
purposes of this Tariff, the amount of gas necessary to fill
a cubic foot of space when the gas is at an absolute pressure
of fifteen and twenty-five thousandths (15.025) pounds per
square inch and at a base temperature of sixty (60) degrees
Fahrenheit. Such amount shall be reported in compliance with
GISB Standard 2.3.9 which is incorporated herein by
Reference.