K N Wattenberg Transmission LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/01/1993, Docket: CP92-203-002, Status: Effective
Original Sheet No. 47 Original Sheet No. 47 : Effective
General Terms and Conditions - continued
(2) Turbine Meters: Installation and the determination
of volumes delivered through turbine meters shall
conform to the recommendations in "Transmission
Measurement Committee Report Number Seven" of the
American Gas Association as amended, revised or
superseded from time to time.
(3) Positive Displacement Meters: Installation and the
determination of volumes delivered shall conform to
the recommendations in "Gas Measurement Manual
Displacement Measurement Part Number Two" of the
American Gas Association as amended, revised or
superseded from time to time.
b. The atmospheric pressure shall be the average atmospheric
pressure as determined by elevation at the Points of
Delivery and Receipt. For the Wattenberg System, this
pressure shall be assumed to be 12.2 psia.
c. The volume of gas delivered through each Point of Delivery
and Receipt shall be corrected to a base temperature of
sixty (60) degrees Fahrenheit by using:
(1) The arithmetic average of the hourly temperatures
recorded by a properly installed continuously
operated recording thermometer; or
(2) A meter containing a temperature operated device,
hereinafter referred to as a temperature compensated
meter, through the operation of which the meter
correctly registers the volume, corrected to sixty
(60) degrees Fahrenheit; or
(3) An assumed temperature of the gas flowing through the
meters of fifty (50) degrees Fahrenheit in the case
of any small volume receipt or delivery where
Transporter does not elect to install a
recording thermometer or temperature compensated