K N Wattenberg Transmission LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/1997, Docket: RP97-144-001, Status: Effective
First Revised Sheet No. 42 First Revised Sheet No. 42 : Effective
Superseding: Original Sheet No. 42
General Terms and Conditions - continued
q. "Gross Dry Heating Value" is the number
of Btus produced by complete combustion,
at a constant pressure, of the amount of
gas which would occupy a volume of 1
cubic foot at a temperature of 60
degrees Fahrenheit on a water-free basis
and at a pressure of 14.73 p.s.i.a. with
air of the same temperature and pressure
as the gas, when the products of
combustion are cooled to the initial
temperature of the gas and air, and when
the water formed by combustion has
condensed to the liquid state.
r. "Imbalance" shall mean the difference
between the Dth of transportation gas
received by the Transporter for the
Shipper's account and the Dth of
transportation gas delivered by the
Transporter to the Shipper or for the
Shipper's account at the Shipper's
Delivery Point, with due regard given to
Fuel Reimbursement.
s. "Interruptible" means that Transporter
has the right to stop, in whole or in
part, receipt, transportation, or
delivery of natural gas at any time.
Transporter shall provide as much
advance notice as is practical to,
Shipper, except as may otherwise be
specifically provided for in this
Tariff.
t. "Interruption" or "reduction" means the
Transporter's inability to provide
transportation to a transportation
customer due to force majeure or
constraints on the pipeline system.
u. "Intra-day Nomination" shall mean a
nomination submitted after the
nomination deadline whose effective time
is no earlier than the beginning of the
gas day and runs through the end of that
gas day.