Original Sheet No. 144 Original Sheet No. 144 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
19. MEASUREMENTS AND TESTS FOR DELIVERY OF NATURAL GAS (Continued)
(d) Temperature. The temperature of the Natural Gas shall be determined at Operator's
option:
(1) where Electronic Measurement equipment is provided, by continuous
application of instantaneous temperature measurements from one or more of the
meters at a measuring station, or by contemporaneous application of the
arithmetic or other average of the temperature record from one or more of the
meters for the time during which gas is flowing;
(2) where Electronic Measurement equipment is not provided,
(i) where an instrument which measures and records the temperature of the
flowing gas is installed, by contemporaneous application of the arithmetic
or other average of the hourly or daily temperature record from one or
more of the meters at a measuring station, or
(ii) where an instrument which measures and records the temperature of the
flowing gas is not installed, by contemporaneous application of the
temperature as read from established tables of monthly averages for the
point of measurement; or
(3) by any other method or methods mutually agreed upon by Operator and Buyer.
(e) Static Pressure. The static pressure of the Natural Gas shall be determined at
Operator's option:
(1) where Electronic Measurement equipment is provided, by continuous application of
instantaneous static pressure measurements from one or more of the meters at a
measuring station, or by contemporaneous application of the arithmetic or other
average of the static pressure record from one or more of the meters for the time
during which gas is flowing;
(2) where Electronic Measurement equipment is not provided, by contemporaneous
application of the static pressure record from one or more of the meters at a
measuring station, or by contemporaneous application of the arithmetic or other
average of the hourly or daily static pressure record from one or more of the
meters at a measuring station; or
(3) by any other method or methods mutually agreed upon by Operator and Buyer.