Cove Point LNG Limited Partnership

Second Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 06/14/2000, Docket: RP00-389-000, Status: Effective

Original Sheet No. 144 Original Sheet No. 144 : Effective

 

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

 

 

19. MEASUREMENTS AND TESTS FOR DELIVERY OF NATURAL GAS (Continued)

 

(d) Temperature. The temperature of the Natural Gas shall be determined at Operator's

option:

 

(1) where Electronic Measurement equipment is provided, by continuous

application of instantaneous temperature measurements from one or more of the

meters at a measuring station, or by contemporaneous application of the

arithmetic or other average of the temperature record from one or more of the

meters for the time during which gas is flowing;

 

(2) where Electronic Measurement equipment is not provided,

 

(i) where an instrument which measures and records the temperature of the

flowing gas is installed, by contemporaneous application of the arithmetic

or other average of the hourly or daily temperature record from one or

more of the meters at a measuring station, or

 

(ii) where an instrument which measures and records the temperature of the

flowing gas is not installed, by contemporaneous application of the

temperature as read from established tables of monthly averages for the

point of measurement; or

 

(3) by any other method or methods mutually agreed upon by Operator and Buyer.

 

(e) Static Pressure. The static pressure of the Natural Gas shall be determined at

Operator's option:

 

(1) where Electronic Measurement equipment is provided, by continuous application of

instantaneous static pressure measurements from one or more of the meters at a

measuring station, or by contemporaneous application of the arithmetic or other

average of the static pressure record from one or more of the meters for the time

during which gas is flowing;

 

(2) where Electronic Measurement equipment is not provided, by contemporaneous

application of the static pressure record from one or more of the meters at a

measuring station, or by contemporaneous application of the arithmetic or other

average of the hourly or daily static pressure record from one or more of the

meters at a measuring station; or

 

(3) by any other method or methods mutually agreed upon by Operator and Buyer.