Cove Point LNG Limited Partnership
Second Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/2003, Docket: CP01- 76-004, Status: Effective
Substitute First Revised Sheet No. 122 Substitute First Revised Sheet No. 122 : Effective
Superseding: Original Sheet No. 122
GENERAL TERMS AND CONDITIONS
(Continued)
7. FLEXIBLE PRIMARY AND SECONDARY RECEIPT AND DELIVERY POINTS (Continued)
(b) Flexible Primary Receipt and Delivery Point Authority. Except for the Receipt Point
for LNG tendered to Operator under Rate Schedules LTD-1, FPS-1, FPS-2, FPS-3 and
Section 11 (LNG Inventory Transfers) of the General Terms and Conditions, and except
as may otherwise be specified in this Section or in individual Rate Schedules, Buyers
under Rate Schedules LTD-1, FTS, FPS-1, FPS-2 and FPS-3 shall have flexible primary
Receipt and Delivery Point authority; provided that Operator, in its reasonable
discretion, determines that sufficient firm capacity exists in its existing facilities
to accommodate the proposed changes in primary Receipt or Delivery Points. Any Buyer
seeking to change primary Receipt or Delivery Points under an existing Service
Agreement shall request such a change by advising Operator, identifying the Service
Agreement affected, and furnishing Operator with the information described in Section
3 (Requests for Service) of the General Terms and Conditions. If firm capacity is
available to accommodate Buyer's requested change, Operator and Buyer shall execute an
agreement, superseding Appendix A to the relevant Service Agreement, that shall
reflect the agreed changes in such Receipt or Delivery Points, or maximum daily
quantities.
(c) Secondary Receipt and Delivery Point Authority. Except as provided in Paragraph (b)
above or elsewhere in this Tariff, Buyer may have secondary Receipt and Delivery
Points under any firm Service Agreement as provided and subject to the requirements in
the applicable Rate Schedule. Receipts and deliveries of Natural Gas at such
secondary Receipt and Delivery Points shall have the allocation priority as described
in Section 15 (Capacity Allocation) of the General Terms and Conditions, and Operator
shall interrupt service at such secondary Receipt and Delivery Points for the same
reasons and in the same manner as interruptible services at such points, as set forth
in Section 16 (Interruptions of Service) of the General Terms and Conditions. The
list of interconnections at which secondary point service is available will be
maintained by Operator in a Master List of Interconnections (MLI) posted on its EBB.
The interconnection points on the MLI shall be incorporated, where appropriate, as
secondary points in Buyer's Service Agreement.
8. NATURAL GAS QUALITY
(a) General Requirement. Natural Gas received by Operator and delivered to Buyer
hereunder shall at all times conform to the quality provisions set forth in this
Section. Neither Operator nor Buyer shall be required to receive Natural Gas from the
other or for Buyer's account which does not conform to the requirements of this
Section. Buyer shall indemnify Operator and save it harmless from all suits, actions,
regulatory proceedings, damages, costs, losses and expenses (including reasonable
attorney fees) arising out of the failure of said Natural Gas to conform to such
quality provisions. Operator shall indemnify Buyer and save Buyer harmless from all
suits, actions, regulatory proceedings, damages, costs, losses and expenses (including
reasonable attorney's fees) arising out of the failure of the Natural Gas to conform
to such provisions.