TSS RATE SCHEDULE

Trans-Storage Service

 

TSS-P Production Area

TSS-M Market Area

 

2. APPLICABILITY AND CHARACTER OF SERVICE

 

(a) This rate schedule shall apply to transportation and storage of

gas by WNG pursuant to the executed TSS Service Agreement.

 

(b) Service under this rate schedule shall be on a firm basis up to

the MDTQ for each area, the MDIQ and MDWQ for storage and the MDQ

for each Primary Receipt and Primary Delivery Point specified in

the executed TSS Service Agreement. Service shall consist of the

acceptance by WNG of natural gas tendered by Shipper at the

Primary Receipt Point(s) on WNG's system specified in the

executed TSS Service Agreement, the storage of gas, the

transportation of such gas through WNG's pipeline system, and the

delivery of a quantity of natural gas on a no-notice basis with

the thermal equivalent of the quantity received at the Primary

Receipt Point(s) and from storage, after the appropriate

reductions for fuel and loss, up to the MDTQ for each area and

the MDQ's specified in the executed TSS Service Agreement, to

Shipper or for Shipper's account at the Primary Delivery Point(s)

on WNG's system specified in the executed TSS Service Agreement.

Shippers may also utilize secondary receipt and delivery points

as specified in Article 4 of the General Terms and Conditions.

 

(c) Gas stored under this rate schedule may be sold in place to other

parties having sufficient available Rate Schedules FSS or ISS

storage capacity. Parties wishing to make sales of gas in place

must obtain confirmation from WNG two (2) days prior to the

proposed effective date of such sale that the quantity proposed

to be sold is available and shall notify WNG in writing that such

sale has occurred by the effective date of the transaction.

 

(d) Any Shipper under this rate schedule shall specify a MDTQ by area

in the executed Trans-Storage Service Agreement. When Shipper

requires deliveries at its MDTQ, no more than one-half of the

total deliveries of gas shall be from flowing supply sources and

no more than one-half of the total deliveries of gas shall be

from storage. Shippers under Rate Schedule TSS-M shall have

transportation quantity rights in the market area equal to the

MDTQ of the service agreement, firm storage withdrawal rights

equal to one-half of the MDTQ of the service agreement, and

transportation quantity rights in the production area (if