Carnegie Interstate Pipeline Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 01/01/1995, Docket: CP93-552-003, Status: Effective
Original Sheet No. 53 Original Sheet No. 53 : Effective
Superseding: Original Sheet No. 53
GENERAL TERMS AND CONDITIONS
(Continued)
6.1 (Continued)
(d) Where the quantity of gas requires the
determination of heating value (Btu), a
recording calorimeter to continuously measure
and record the heating value (Btu) shall be
provided at a location which will measure the
Btu content of the gas delivered, or at a
mutually agreeable location unless alternative
heating value (Btu) determination methods are
mutually agreed upon by Customer and CIPCO.
6.2 Check Measurement Equipment
Customer may install, operate, and maintain, at
its own expense, such check measurement equipment as
it shall desire, provided that such equipment shall
be so installed as not to interfere with the
operation of other, including CIPCO's, measurement
equipment at or near the Delivery Point(s). CIPCO
shall have access to such check measurement equipment
at all reasonable hours, but the reading,
calibrating, and adjusting thereof and the changing
of charts shall be done only by Customer.
6.3 Access to Equipment and Records
Each party shall have the right to be present at
the time of any installing, reading, cleaning,
changing, repairing, inspecting, testing,
calibrating, or adjusting done in connection with the
other's measurement equipment used in measuring
deliveries hereunder. The records from such
measurement equipment shall remain the property of
their owner, but upon request each will submit to the
other its records and charts, together with
calculations therefrom, for inspection and
verification, subject to return within thirty (30)
days after receipt thereof.
6.4 Pressure Protection
Pressure regulation, pressure override, and
pressure relief valve or other pressure limiting
devices installed and operated by CIPCO at the
measuring station or near each primary or secondary
Delivery Point shall only be for the purpose of
operation and protection of CIPCO's measurement
equipment and CIPCO's facilities.