Carnegie Interstate Pipeline Company

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 01/01/1995, Docket: CP93-552-005, Status: Effective

Sub Original Sheet No. 47 Sub Original Sheet No. 47 : Effective

Superseding: Original Sheet No. 47

GENERAL TERMS AND CONDITIONS

(Continued)

 

3.4 (Continued)

 

(b) Shall not have an uncombined oxygen

content in excess of two tenths of one percent

(0.2%) by volume, and all parties shall make

every reasonable effort to keep the gas free

from oxygen.

 

(c) Shall not contain more than four

percent (4%) by volume, of a combined total of

carbon dioxide and nitrogen; provided however,

the total carbon dioxide content shall not

exceed three percent (3%) by volume.

 

(d) Shall be free of water and

hydrocarbons in liquid form at the temperature

and pressure at which the gas is received and

delivered.

 

(e) Shall not contain more than one grain

(16 ppm) of hydrogen sulfide per one hundred

(100) cubic feet.

 

(f) Shall not contain more than twenty

(20) grains of total sulfur, excluding any

mercaptan sulfur, per one hundred (100) cubic

feet.

 

(g) Shall not have a temperature of more

than one hundred twenty degrees (120)

Fahrenheit.

 

(h) Shall not contain, either in the gas

or in any liquids with the gas, any

microbiological organism, active bacteria, or

bacterial agent capable of contributing to or

causing corrosion and/or operational and/or

other problems. Microbiological organisms,

bacteria, or bacterial agents include, but are

not limited to, sulfate reducing bacteria (SRB)

and acid producing bacteria (APB). Tests for

bacteria or bacterial agents shall be conducted

on samples taken from the meter run or the

appurtenant piping using test methods mutually

agreed upon by Customer and CIPCO.