Carnegie Interstate Pipeline Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 01/01/1995, Docket: CP93-552-003, Status: Effective
Original Sheet No. 45 Original Sheet No. 45 : Effective
Superseding: Original Sheet No. 45
GENERAL TERMS AND CONDITIONS
(Continued)
3.2 (Continued)
(b) The total heating value shall be
determined by a heating value measuring device,
or by other methods mutually agreed upon by
Customer and CIPCO.
(c) The average total heating value of the
gas shall be determined for any billing period
by methods mutually agreed upon by Customer and
CIPCO.
3.3 Composition
Except as provided in Section 3.4, the gas
received or delivered hereunder:
(a) Shall be commercially free under
continuous gas flow conditions from
objectionable odors (except as provided in
Section 3.7), solid matter, dust, gum, and gum-
forming constituents which might interfere with
its merchantability or cause injury to or
interference with proper operations of the
pipelines, compressor stations, meters,
regulators, or other appliances through which it
flows.
(b) Shall not have an uncombined oxygen
content in excess of two tenths of one percent
(0.2%) by volume, and all parties shall make
every reasonable effort to keep the gas free
from oxygen.
(c) Shall not contain more than four
percent (4%) by volume, of a combined total of
carbon dioxide and nitrogen; provided however,
the total carbon dioxide content shall not
exceed three percent (3%) by volume.
(d) Shall be free of water and
hydrocarbons in liquid form at the temperature
and pressure at which the gas is received and
delivered.
(e) Shall not contain more than one half
(0.5) grain (8 ppm) of hydrogen sulfide per one
hundred (100) cubic feet.