4.1 The natural gas delivered at the Point(s) of Receipt and the
Point(s) of Delivery under an executed Service Agreement shall
contain a heating value of not less than 975 Btu per cubic
foot. The heating value shall be determined by Transporter by
the installation of a recording calorimeter, a continuous
sample accumulator, an on-stream chromatograph, or by means of
spot samples; provided, however, that in lieu of a recording
calorimeter, Transporter may determine the heat content on the
basis of samples taken at periodic intervals. If periodic
determinations of heating value are made, the initial
determination is to be made within sixty (60) days after the
date of initial deliveries of natural gas under an executed
Service Agreement and subsequent determinations shall be made
each three (3) months thereafter. The recording calorimeter
mentioned herein shall be tested periodically using a reference
sample of natural gas of known heating value.