3.3 The temperature of the natural gas shall be determined at the
point of measurement by means of recording thermometers of
standard manufacture acceptable to Transporter and Shipper to
be installed in accordance with the recommendations contained
in Gas Measurement Report No. 3, as aforesaid.
3.4 The specific gravity of the natural gas shall be determined at
the point of measurement by one of the following methods:
a. By means of a properly installed recording gravitometer
of standard manufacture acceptable to Transporter and
Shipper, or
b. By use of a portable specific gravity balance of
standard manufacture acceptable to Transporter and
Shipper, such determination to be made at least once
every six (6) months, or
c. By means of a calculated specific gravity derived from a
gas chromatograph determination.
3.5 Unless otherwise agreed upon, Transporter will install,
maintain and operate or cause to be installed, maintained and
operated measuring stations equipped with orifice meters and
other necessary metering and measuring equipment by which the
volumes of natural gas received and delivered under an executed
Service Agreement shall be determined. Orifice meters shall
be installed and operated in accordance with said Gas
Measurement Committee Report No. 3. Shipper may install check
measuring equipment at its own cost and expense; provided,
however, that such equipment shall be so installed as not to
interfere with the operations of Transporter. Transporter and
Shipper, in the presence of each other, shall have access to
the other's measuring equipment at all reasonable times, but
the reading, calibrating and adjusting thereof and the changing
of charts shall be done only by the equipment owner or such
owner's representative, unless otherwise agreed upon. Both
Transporter and Shipper shall have the right to be present at
the time of any installing, reading, cleaning, changing,
repairing, inspecting, testing, calibrating, or adjusting done
in connection with the other's measuring equipment; provided,
however, failure of either Transporter or Shipper to witness
such an operation shall not affect the validity of such
operation in any way. The records from such measuring
equipment shall remain the property of their owner, but upon
request, each will submit to the other its records and charts,
together with calculations therefrom, for inspection, subject
to return within thirty (30) days after receipt thereof. The
measurement equipment of Shipper shall be for check purposes
only and, except as expressly provided in an executed Service