Reliant Energy Gas Transmission Company
Fourth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/01/1997, Docket: RP97- 61-002, Status: Effective
First Revised Sheet No. 175 First Revised Sheet No. 175 : Effective
Superseding: Original Sheet No. 175
GENERAL TERMS AND CONDITIONS
(continued)
Report No. 3 ANSI/API 2530, as amended from
time to time, unless otherwise agreed.
(e) The Gross Heating Value shall be determined
by using a suitably located and reasonably
acceptable calorimeter or calculation from
fractional analysis by an acceptable
chromatograph, according to the methods
outlined in the AGA Measurement Committee
Report No. 5, as amended from time to time,
unless otherwise agreed. The Gross Heating
Value so determined shall be corrected from
the conditions of testing to that of the
actual condition of the Gas as delivered
(including the conversion from saturated to
dry conditions) expressed in Btu per cubic
foot and reported at a pressure base of 14.73
psia; provided, however, if the Gas as
delivered contains seven (7) pounds of water
or less per one million (1,000,000) cubic
feet, such Gas shall be assumed to have zero
(0) pounds of water per one million
(1,000,000) cubic feet (dry Gas).
2.4 Examination of Records. Upon request, the
measuring party shall make its measurement charts
and records available to the other party for
examination, the same to be returned within twenty
(20) Days; provided, however, that the measuring
party shall not be required to provide any such
records or charts more often than once in any
three (3) month period. Transporter's charts and
records for a given Service Month shall be
conclusively presumed correct if no written
objection thereto is served on Transporter in
accordance with the provision of Section 14.4
below. Records will be retained for a period of
two Years.
2.5 Closing of Measurement. Transporter will close
measurement no later than five (5) Business Days
after the end of the applicable Service Month, in
accordance with GISB Standard 2.3.7.