Reliant Energy Gas Transmission Company

Fourth Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/1998, Docket: RP96-200-034, Status: Effective

Sixth Revised Sheet No. 7D Sixth Revised Sheet No. 7D : Effective

Superseding: Fifth Revised Sheet No. 7D

 

Statement of Negotiated Rates

 

Contract Rate Contract

Shipper Name Number Schedule Demand Receipt Point(s) Delivery Point(s) Rate

------------ --------- -------- -------- ---------------- ------------------ -----

 

Amoco Energy Trading Corporation 1002186 FT 15,000 East Mountain Production Area TGT @ Perryville See Formula below

Blocker Production Area ANR @ Perryville

Neutral Pooling Area (East of Chandler) Koch @ West Monroe

North Pooling Area (East of Chandler) Tennessee 100 @ Perryville

South Pooling Area (East of Chandler) Tennessee 800 @ Perryville

Trunkline @ Richland

TET @ West Monroe

SONAT @ Perryville

 

 

 

Formula Rates for Services up to Contract Demand:

 

The formula rate shall be based on the index prices ("Index Prices") for spot gas delivered to the pipelines at the areas indicated, as published in the first

issue of the Month of Inside FERC's Gas Market Report for the Service Month.

 

If the information or publication ceases to be published, the parties shall select another mutually agreeable Index Price

 

The unit rate per Dth of Contract Demand shall never be less than $0.02 (the "Floor Rate"). The Index Spread shall be the difference between the Index Prices

specified in (1) and (2) below

 

(1) NorAm Gas Transmission (East)

(2) Texas Gas Transmission Corp (Zone SL)

 

If the Index Spread is equal to $0.11, then the unit rate per Dth of Contract Demand shall be $0.11 plus the Floor Rate ($0.02).

If the Index Spread is less than $0.11, then the unit rate shall be the Floor Rate plus the remainder when you subtract (i) 70% of the difference between $0.11

and the Index Spread from (ii) $0.11. If the Index Spread is greater than $0.11, then the unit rate shall be the Floor Rate plus $0.11 plus the product of

(i) 0.6 times (ii) the Index Spread less $0.11.

 

 

In any event, however, the unit rate per Dth of Contract Demand in any Month shall never be below Transporter's then effective minimum Tariff rate. Unless

Transporter agrees otherwise, the rate for any authorized overrun quantities shall be the greater of the applicable maximum Tariff rate or the applicable

formula unit rate.