Reliant Energy Gas Transmission Company
Fifth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2002, Docket: RP03- 60-000, Status: Effective
Second Revised Sheet No. 263 Second Revised Sheet No. 263 : Effective
Superseding: First Revised Sheet No. 263
GENERAL TERMS AND CONDITIONS
(continued)
3. MEASUREMENT EQUIPMENT (continued)
for Point(s) of Receipt or Delivery shall be owned, maintained and
operated, at or near the Point of Receipt or Delivery, as agreed
to by Transporter. Transporter, in addition to any remedies
otherwise available to it, shall retain the right either to
discontinue the operation and maintenance of measuring facilities
when it determines that the daily average flows, determined over a
period of sixty (60) consecutive Days, through any such facility
fall below 75 Mcfd or that to continue such operation and
maintenance would be otherwise economically or operationally
impracticable after posting in advance on its Internet Web Site
the specific criteria to be used in making any such
determinations, or to enter into mutually agreeable reimbursement
arrangements. Where used, orifice meters shall employ flange taps
and shall be installed and operated in accordance with the
referenced AGA Measurement Committee Report No. 3 ANSI/API 2530,
as amended from time to time, unless otherwise agreed. The stated
pressure shall be measured from the downstream flange tap. If
turbine meters are used, they shall be installed and operated in
accordance with the AGA Transmission Measurement Committee Report
No. 7, as amended from time to time, unless otherwise agreed. If
other types of measurement devices or instruments are used, the
installation and operation of such facilities shall be in
accordance with terms and procedures reasonably acceptable to
Transporter, in view of its operational requirements and
constraints.
3.2 Check Meters. Either party shall have the right to install,
maintain and operate, at its own expense, at or near Point(s) of
Receipt and Delivery, check meters and other necessary equipment
by which the quantity of Gas received or delivered by Transporter
may be measured for checking purposes, provided that the
installation or operation shall in no way interfere with the
operation, maintenance and measurement of any primary measuring
facilities at such point(s). Where used, orifice meters shall
employ flange taps and shall be installed and operated in
accordance with the AGA Committee Report No. 3 ANSI/API 2530, as
amended from time to time,