Reliant Energy Gas Transmission Company
Fifth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2002, Docket: RP03- 60-000, Status: Effective
First Revised Sheet No. 261 First Revised Sheet No. 261 : Effective
Superseding: Original Sheet No. 261
GENERAL TERMS AND CONDITIONS
(continued)
2. MEASUREMENT (continued)
Report No. 3 ANSI/API 2530, as amended from time to time,
unless otherwise agreed.
(e) The Gross Heating Value shall be determined by using a
suitably located and reasonably acceptable calorimeter or
calculation from fractional analysis by an acceptable
chromatograph, according to the methods outlined in the AGA
Measurement Committee Report No. 5, as amended from time to
time, unless otherwise agreed. The Gross Heating Value so
determined shall be corrected from the conditions of testing
to that of the actual condition of the Gas as delivered
(including the conversion from saturated to dry conditions)
expressed in Btu per cubic foot and reported at a pressure
base of 14.73 psia; provided, however, if the Gas as
delivered contains seven (7) pounds of water or less per one
million (1,000,000) cubic feet, such Gas shall be assumed to
have zero (0) pounds of water per one million (1,000,000)
cubic feet (dry Gas).
2.4 Examination of Records. Upon request, the measuring party shall
make its measurement charts and records available to the other
party for examination, the same to be returned within twenty (20)
Days; provided, however, that the measuring party shall not be
required to provide any such records or charts more often than
once in any three (3) Month period. Transporter's charts and
records for a given Service Month shall be conclusively presumed
correct if no written objection thereto is served on Transporter
in accordance with the provision of Section 14.4 below. Records
will be retained for a period of two Years.
2.5 Closing of Measurement. Transporter will close measurement no
later than five (5) Business Days after the end of the applicable
Service Month, in accordance with NAESB Standard 2.3.7.