10. QUALITY
10.1 Gas Delivered by or on behalf of the Customer to Caledonia shall
conform to the Third Party Transporter’s gas quality standards. In the
event that Gas scheduled for Delivery by Customer fails to meet such
quality specifications, Caledonia shall have the right to refuse to
accept Delivery of such Gas for so long as such condition exists. Gas
Re-Delivered by Caledonia shall conform to the Third Party
Transporter’s quality standards; provided, however, that if the Gas
tendered for Delivery to Customer by Caledonia is substantially the
same quality in all material respects as the quality of Gas that
Customer Delivered to Caledonia, then it shall be deemed to have
complied in all respects with its Delivery obligations to Customer
hereunder.
10.2 Specifications. The Gas tendered by Customer to Caledonia for
injection or made available by Caledonia to Customer upon withdrawal
at the Point of Injection/Withdrawal shall be of such quality that it
shall meet at least the following specifications (“Required
Specifications”):
(a) shall have a total heating value of not less than nine hundred
sixty-seven (967) Btus per cubic foot, and not more than one thousand
seventy (1070) Btus per cubic foot; (b) shall be commercially free (at
prevailing pressure and temperature in Caledonia’s Storage Facility)
from objectionable odors, dust, gums and gum forming constituents,
solid matter, hydrocarbon liquids, water and any other substance that
might become separated from the Gas in Caledonia’s Storage Facility or
that interferes with the merchantability of the Gas or causes
interference with the proper and safe operation of the pipeline,
meters, regulators and other facilities through which such Gas will
flow;
(b) shall not contain more than twenty (20) grains of total sulphur,
nor more than one fourth (1/4) of one grain of hydrogen sulphide per
one hundred (100) cubic feet;
(c) shall not contain more than two-tenths of one percent (0.2%) by
volume of oxygen, and Customer shall make every reasonable effort to
keep the gas free of oxygen;
(d) shall not contain more than four percent (4%) by volume of a
combined total of carbon dioxide and nitrogen components; provided,
however, that the total carbon dioxide content shall not exceed two
percent (2%) by volume and the total nitrogen content shall not exceed
three percent (3%) by volume;