Caledonia Gas And Storage

First Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 09/30/2010, Docket: RP10-1032-000, Status: Effective

Original Sheet No. 96 Original Sheet No. 96

 

10. QUALITY

10.1 Gas Delivered by or on behalf of the Customer to Caledonia shall

conform to the Third Party Transporter’s gas quality standards. In the

event that Gas scheduled for Delivery by Customer fails to meet such

quality specifications, Caledonia shall have the right to refuse to

accept Delivery of such Gas for so long as such condition exists. Gas

Re-Delivered by Caledonia shall conform to the Third Party

Transporter’s quality standards; provided, however, that if the Gas

tendered for Delivery to Customer by Caledonia is substantially the

same quality in all material respects as the quality of Gas that

Customer Delivered to Caledonia, then it shall be deemed to have

complied in all respects with its Delivery obligations to Customer

hereunder.

10.2 Specifications. The Gas tendered by Customer to Caledonia for

injection or made available by Caledonia to Customer upon withdrawal

at the Point of Injection/Withdrawal shall be of such quality that it

shall meet at least the following specifications (“Required

Specifications”):

(a) shall have a total heating value of not less than nine hundred

sixty-seven (967) Btus per cubic foot, and not more than one thousand

seventy (1070) Btus per cubic foot; (b) shall be commercially free (at

prevailing pressure and temperature in Caledonia’s Storage Facility)

from objectionable odors, dust, gums and gum forming constituents,

solid matter, hydrocarbon liquids, water and any other substance that

might become separated from the Gas in Caledonia’s Storage Facility or

that interferes with the merchantability of the Gas or causes

interference with the proper and safe operation of the pipeline,

meters, regulators and other facilities through which such Gas will

flow;

(b) shall not contain more than twenty (20) grains of total sulphur,

nor more than one fourth (1/4) of one grain of hydrogen sulphide per

one hundred (100) cubic feet;

(c) shall not contain more than two-tenths of one percent (0.2%) by

volume of oxygen, and Customer shall make every reasonable effort to

keep the gas free of oxygen;

(d) shall not contain more than four percent (4%) by volume of a

combined total of carbon dioxide and nitrogen components; provided,

however, that the total carbon dioxide content shall not exceed two

percent (2%) by volume and the total nitrogen content shall not exceed

three percent (3%) by volume;