Riverside Pipeline Company, L. P.

First Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 10/01/1993, Docket: RS92- 48-001, Status: Effective

Original Sheet No. 69 Original Sheet No. 69 : Effective

 

 

GENERAL TERMS AND CONDITIONS

 

 

3. MEASURING EQUIPMENT

 

3.1 Installation: At each Point of Receipt and Delivery hereunder,

Riverside shall install, own, maintain and operate all necessary

measuring equipment and devices, unless provided otherwise in

Exhibit A of the executed Service Agreement. Shipper may install

and operate check measuring equipment provided it does not

interfere with the use of Riverside's equipment.

 

3.2 Testing Meter Equipment: Riverside's meter or meters shall be

open to inspection by Shipper in the presence of Riverside.

Riverside shall test its meters for accuracy of measurement

quarterly or as often as Riverside deems advisable. Notice of the

time and nature of each test shall be given by Riverside to

Shipper sufficiently in advance to permit convenient arrangement

for the presence of the representative of Shipper. If after

notice Shipper fails to have a representative present, the results

of the test shall nevertheless be considered accurate until the

next test. If any of the measuring equipment is found to be

registering inaccurately in any percentage it shall be adjusted at

once to read as accurately as possible. A registration within two

percent (2%) of correct shall be considered correct as to

deliveries prior to the test.