Riverside Pipeline Company, L. P.
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/01/1993, Docket: RS92- 48-001, Status: Effective
Original Sheet No. 69 Original Sheet No. 69 : Effective
GENERAL TERMS AND CONDITIONS
3. MEASURING EQUIPMENT
3.1 Installation: At each Point of Receipt and Delivery hereunder,
Riverside shall install, own, maintain and operate all necessary
measuring equipment and devices, unless provided otherwise in
Exhibit A of the executed Service Agreement. Shipper may install
and operate check measuring equipment provided it does not
interfere with the use of Riverside's equipment.
3.2 Testing Meter Equipment: Riverside's meter or meters shall be
open to inspection by Shipper in the presence of Riverside.
Riverside shall test its meters for accuracy of measurement
quarterly or as often as Riverside deems advisable. Notice of the
time and nature of each test shall be given by Riverside to
Shipper sufficiently in advance to permit convenient arrangement
for the presence of the representative of Shipper. If after
notice Shipper fails to have a representative present, the results
of the test shall nevertheless be considered accurate until the
next test. If any of the measuring equipment is found to be
registering inaccurately in any percentage it shall be adjusted at
once to read as accurately as possible. A registration within two
percent (2%) of correct shall be considered correct as to
deliveries prior to the test.