GENERAL TERMS AND CONDITIONS (cont'd)
3. MEASUREMENT (cont'd)
3.3 (cont'd)
3.3.1 The H2S and CO2 concentration of the gas shall
be determined by chromatograph or other
industry accepted instruments as may be
mutually agreed upon by Shipper/Shipper's
Agent and Transporter and installed so as to
continuously monitor the composition of the
gas.
3.3.2 Shipper/Shipper's Agent shall record on a
continuous basis the following gas stream
information and communicate such information
to Transporter's control center:
a) gas volume b) H2S concentration
c) heating value d) flow temperature
e) water content f) flow pressure at
receipt point
In the event of multiple Shippers and/or gas
supplies, Shipper/Shipper's Agent(s) may be
required to install facilities to telemeter
the above gas stream information and also:
a) CO2 concentration b) specific gravity
3.3.3 The water content of the gas shall be
determined by the use of a moisture analyzer
as may be mutually agreed upon by
Shipper/Shipper's Agent and Transporter and
installed so as to continuously monitor the
moisture content of the gas.
3.3.4 Notwithstanding the provisions of this
Section, in no event shall any existing
Shipper or existing facility connected to the
pipeline be required to install new equipment
to meet these standards unless required to do
so by government action.