High Island Offshore System, L.L.C.
Third Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/01/2007, Docket: RP06-540-004, Status: Effective
Third Revised Sheet No. 79 Third Revised Sheet No. 79 : Effective
Superseding: Substitute Second Revised Sheet No. 79
GENERAL TERMS AND CONDITIONS
(Continued)
3.6(a) By use of Burnett type apparatus. Such determination shall be
made within 60 days of commencement of service under Rate
Schedules FT-1, FT-2, and IT and annually thereafter.
3.6(b) Or, if agreeable to Shipper, by use of the tables or formulas
published in the applicable American Gas Association Report
referred to in Section 3.6. Determinations of the molecular
percentage of nitrogen and carbon dioxide in the Gas will be made
within 30 days of commencement of deliveries under Rate Schedules
FT-1, FT-2, and IT and at least quarterly thereafter. The
molecular percentage of nitrogen and carbon dioxide thus
determined will be used to determine the supercompressibility
factors during the ensuing period with corrections for specific
gravity, temperature and pressure.
3.7 Measuring Equipment. Unless otherwise agreed upon, Shipper will cause to
be provided, maintained, and operated necessary offshore platforms and
measuring and regulating stations equipped with flow meters, continuous
gas sampler and other necessary measuring equipment by which its volumes
of gas delivered to HIOS hereunder shall be determined. Unless otherwise
agreed upon, HIOS shall cause to be installed, operated and maintained at
its expense a measuring and regulating station or stations equipped with
flow meters, gas analyzer and other necessary measuring equipment for the
measurement of gas redelivered to or for the account of Shipper; such
measuring and regulating stations shall be so installed at the northern
terminus of the System or one shall be installed at each of two mutually
agreeable points onshore in the vicinity of Johnson's Bayou and Lower Mud
Lake, Louisiana to provide measurement on a compatible basis. All flow,
measuring, testing, and related equipment shall be of standard
manufacture and type approved by HIOS, and the size, type, and
specifications of such