Enbridge Offshore Pipelines (Utos) LLC
FIFTH REVISED VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/01/2009, Docket: RP09-815-000, Status: Effective
First Revised Sheet No. 111 First Revised Sheet No. 111
Superseding: Original Sheet No. 111
GENERAL TERMS AND CONDITIONS
(Continued)
3.4 Temperature. The temperature of the Gas shall be
determined at each point of measurement by means of a
properly installed recording thermometer or temperature
transmitter of standard manufacture acceptable to both
parties.
3.5 Specific Gravity. The specific gravity of the Gas shall
be determined at each point of measurement by continuous
sampler or other methods mutually agreeable to both
parties.
3.6 Supercompressibility. The supercompressibility of the
Gas (deviation from the laws for ideal gases) shall be
determined by one of the following methods:
(a) By use of Burnett type apparatus. Such
determination to be made within 30 Days of
commencement of service under Rate Schedules FT and
IT and annually thereafter.
(b) Or, if agreeable to Shipper, by use of the tables
or, formulae published by the American Gas
Association in conjunction with the Gas Measurement
Committee Report referred to in Section 3.6.
Determinations of the molecular percentage of
nitrogen and carbon dioxide in the Gas will be made
within 30 Days of commencement of deliveries under
Rate Schedules FT and IT and at least quarterly
thereafter. The molecular percentage of nitrogen
and carbon dioxide thus determined will be used to
determine the supercompressibility factors during
the ensuing period, with corrections for specific
gravity, temperature and pressure.