12. MEASUREMENT
12.1 The unit of volume for the purpose of measurement and the
determination of total heating value of all quantities of Gas
stored by Bobcat or delivered to and received from storage
hereunder shall be one (1) cubic foot of Gas at the base
temperature of sixty degrees Fahrenheit (60 degrees F) and at an
absolute pressure of fourteen and seventy-three hundredths (14.73)
pounds per square inch and dry. All fundamental constants,
observations, records, and procedures involved in determining
and/or verifying the quantity and other characteristics of Gas
delivered hereunder shall, unless otherwise specified herein, be
in accordance with the standards prescribed in Report No. 3 of the
American Gas Association, as now in effect and from time to time
amended or supplemented. All measurements of Gas shall be
determined by calculation into terms of such unit. All quantities
given herein, unless expressly stated otherwise, are terms of such
unit. Notwithstanding the foregoing, it is agreed that, for all
purposes, the Btu content of the Gas received and delivered by
Bobcat hereunder shall be measured on a "dry" basis rather than a
fully saturated or "wet" basis. For Gas volumes reported in cubic
meters, the standard conditions are 101.325 kPa, 15 degrees C, and
dry.
12.2 Bobcat shall install, maintain, and operate, or cause to be
installed, maintained, and operated, the measurement facilities
required hereunder. Said measurement facilities shall be so
equipped with meters, recording gauges, chromatographs, or other
types of related and/or similar equipment of standard make and
design commonly acceptable in the industry, as to accomplish the
accurate measurement of Gas delivered hereunder. The retrieval of
data and calibrating and adjustment of meters shall be done by
Bobcat or its agent.
12.3 The unit of gas received, injected, stored, withdrawn, and
delivered shall be measured as one million Btu's (1,000,000 Btu),
as defined in Section 2 (Definitions) of these General Terms and
Conditions. The number of Btu's received, injected, stored,
withdrawn, and delivered shall be determined by multiplying the
number of cubic feet of Gas determined pursuant to Section 12.1 of
these General Terms and Conditions by the total heating value of
such gas, in BTUs per cubic foot, rounded to not less than 6
decimal places and by dividing the product by one million
(1,000,000).