Bobcat Gas Storage
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/15/2008, Docket: RP08-608-000, Status: Effective
Original Sheet No. 90 Original Sheet No. 90
GENERAL TERMS AND CONDITIONS
(Continued)
7. NOMINATIONS AND SCHEDULING (Continued)
7.2 Bobcat will accept nominations for service as follows: (Continued)
(f) Minimum NAESB Nomination Standards (Continued)
(4) The Intraday 2 Nomination Cycle: 5:00 p.m. for
nominations leaving control of the nominating party;
5:15 p.m. for receipt of nominations by Bobcat
(including from TTTSPs); 5:30 p.m. to send Quick
Response; 8:00 p.m. for receipt of completed
confirmations by Bobcat from upstream and downstream
connected parties; 9:00 p.m. for Bobcat to provide
scheduled quantities to affected Customers and point
operators, and to provide scheduled quantities to
bumped parties (notice to bumped parties) (Central
Clock Time on the Day). Scheduled quantities
resulting from Intraday 2 Nominations should be
effective at 9:00 p.m. on the Day. Bumping is not
allowed during the Intraday 2 Nomination Cycle.
For purposes of Sections 7.2(f)(2) through 7.2(f)(4),
"provide" shall mean, for transmittals pursuant to NAESB
Standards 1.4.x, receipt at the designated site, and for
purposes of other forms of transmittal, it shall mean send
or post.
7.3 Customer shall make available and tender any Gas to be injected
hereunder and receive and accept delivery upon tender by Bobcat
any Gas requested by Customer to be withdrawn from storage. The
quantity of Gas stored for the account of Customer shall be
increased or decreased upon injection or withdrawal of Gas from
storage, as applicable. Customer shall not (unless otherwise
agreed by Bobcat) receive or deliver Gas, nor shall Bobcat be
obligated to receive Gas or deliver Gas on an hourly basis at
rates of flow in excess of 1/24 of Customer's MDIQ or MDWQ. As
determined by Bobcat in its sole and reasonable judgment, flow
rates above 1/24 of Customer's MDIQ or MDWQ may be permitted.