ANR Storage Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/01/2007, Docket: RP08- 16-000, Status: Effective
First Revised Sheet No. 138 First Revised Sheet No. 138 : Effective
Superseding: Original Sheet No. 138
GENERAL TERMS AND CONDITIONS
(Continued)
(6) The compressibility ratio factor "s" used in
computing the volume of Gas delivered through a
turbine meter or a positive displacement meter
shall be determined by the equation s = (Fpv)2, in
which "Fpv" is the supercompressibility factor
determined as described in subparagraph (4) of
this subsection (b), above.
(7) In determining the flowing temperature factor,
supercompressibility factor, and compressibility
ratio factor "s" for use in computing the volume
of Gas delivered through a meter, the flowing Gas
temperature for only the period(s) of time that
Gas was flowing through the meter shall be used.
6.3 All flow, measuring, testing and related equipment shall
be of standard manufacture and type approved by Seller.
If applicable, Seller or Customer may install check
measuring equipment, provided that such equipment shall
be so installed as not to interfere with the operations
of the Operator. Seller, or Customer, in the presence
of the other party, shall have access to measuring
equipment at all reasonable times, but the reading,
calibrating, and adjusting thereof and the changing of
charts, if any, shall be done by the Operator. Seller
or Customer shall have the right to be present at the
time of the installing, reading, cleaning, changing,
repairing, inspecting, testing, calibrating or adjusting
done by the Operator of the measuring equipment. The
records from such measuring equipment shall remain the
property of the Operator, but upon request, the other
party may request records, including charts, if any,
together with calculations therefrom for inspection,
subject to return within thirty (30) Days after receipt
thereof. Reasonable care shall be exercised in the
installation, maintenance and operation of the measuring
equipment so as to avoid any inaccuracy in the
determination of the volume of Gas injected and
withdrawn. The accuracy of all measuring equipment
shall be verified by Operator at reasonable intervals,
and if requested, in the presence of representatives of
the other party, but neither Seller nor Customer shall
be required to verify the accuracy of such equipment
more frequently than once in any thirty (30) Day period.
If either party at any time desires a special test of
any measuring equipment, it will promptly notify the
other party