Cimarron River Pipeline, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 09/01/2008, Docket: CP08-17-001, Status: Effective

Original Sheet No. 127 Original Sheet No. 127

 

GENERAL TERMS AND CONDITIONS

 

2. QUALITY continued

 

2.2 Dehydration:

 

(a) Transporter provides central dehydration for gas from all of the

Receipt Points on the pipeline segments identified in blue on Transporter's

Dehydration Map and at the Beaver Station. The water vapor quality

specification above will not apply to gas received on these pipeline

segments.

 

(b) Transporter also provides dehydration at the following Receipt

Points:

 

 

TRANSPORTER DEHYDRATION POINTS

 

Point

MID ID. Receipt Point State County

1 96 Northrup Compressor TX Ochiltree

1 2160 Spearman Compressor TX Ochiltree

1 2509 Perryton Compressor TX Ochiltree

1 59945 CNG Gath/NNG Dude Wilson Northrup TX Ochiltree

1 62789 Spearman/Continental Compressor TX Ochiltree

1 63015 NNG/CNG Perryton Barlow TX Ochiltree

1 78865 DCP Perryton Barlow TX Ochiltree

1 71250 NNG/KNGG Spearman Plant PDC TX Ochiltree

1 22160 NNG/WTG Hansford 6 PDC TX Hutchinson

2 6 Beaver County #1 OK Beaver

2 8 Beaver County #2 OK Beaver

4 29 Clark County #1/DCP KS Clark

4 30 Clark County #2 KS Clark

4 78107 Clark Co. #1/ONEOK KS Clark

 

The water vapor quality specification above will not apply to gas received

at these Receipt Points.

 

(c) Except as stated in (b) above, Transporter is not obligated to

provide dehydration at any other Receipt Points at any time on the pipeline

segments in black on the Dehydration Map.