Kinder Morgan Louisiana Pipeline LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 03/01/2009, Docket: RP09-257-000, Status: Effective

Original Sheet No. 228 Original Sheet No. 228

 

GENERAL TERMS AND CONDITIONS

----------------------------

 

(c) KMLP, from time to time, will accept Gas that is

above the upper Btu and Wobbe limits set forth in Sections (a)(9)

and (a)(11) hereof, respectively, as set forth herein:

 

(i) KMLP shall accept gas with a Btu content in

excess of 1110 Btu/cf at specific points posted on KMLP's website

provided that Shipper provides gas treatment including nitrogen

injection and/or processing, prior to the point at which such gas

reaches any Point of Delivery on the KMLP system, sufficient to

reduce the Btu content of the Gas to less than 1110 Btu/cf, and

that acceptance of such gas is operationally feasible.

 

(ii) KMLP shall accept gas with a Wobbe Index in

excess of 1400 at specific points posted on KMLP's website provided

that Shipper provides gas treatment including nitrogen injection

and/or processing, prior to the point at which such gas reaches any

Point of Delivery on the KMLP system, sufficient to reduce the

Wobbe Index of the Gas to less than 1400, and that acceptance of

such gas is operationally feasible.

 

(d) With respect to any quantities of Gas nominated for

transportation through the Leased Capacity on NGPL referenced in

Section 1.20, Shipper's Gas will be required to comply with the

quality specifications of Natural Gas Pipeline Company of America

LLC's FERC Gas Tariff as in effect from time to time.

 

19.2 LIQUIDS SAMPLE

 

Shipper agrees to supply or cause its designee to supply

to KMLP upon demand, at any time and from time to time, a sample of

liquids removed from the Gas stream at any Receipt Point, whether

removed by a coalescer or otherwise, for analysis at a laboratory

of KMLP's choosing. If at any time PCBs or any other toxic

substances or chemicals that KMLP deems hazardous and/or in any way

unsafe for transportation are found in the liquid samples supplied

to KMLP by Shipper, KMLP may in its sole discretion immediately

cease the receipt of such Gas and any associated liquids through

its facilities. Upon proof that such toxic or hazardous substances

are no longer present at levels deemed unsafe by KMLP, KMLP shall

restore service to Shipper at the affected Receipt Point.