Kinder Morgan Louisiana Pipeline LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 03/01/2009, Docket: RP09-257-000, Status: Effective

Original Sheet No. 227 Original Sheet No. 227

 

GENERAL TERMS AND CONDITIONS

----------------------------

 

Gas with a Btu content no less than 950 Btu/cf and no greater than

1110 Btu/cf; provided, however, that if the resulting Gas stream

has an average Btu content of less than 1065 Btu/cf, its service

obligation under firm contracts will be adjusted accordingly. To

the extent operationally feasible, KMLP will blend higher and lower

Btu Gas;

 

(10) shall have a combined composition of not more

than one and one-half (1.5) mole percentage of butane plus,

including isobutene, normal butane and all heavier hydrocarbons

(C4+); and

 

(11) shall have a Wobbe Index of not greater than

1400, calculated using Higher Heating Value (HHV), dry, based on

the following mathematical definition:

 

HHV / (Sqrt (SGgas) )

Where:

HHV = Higher Heating Value (Btu/scf)

SGgas = Specific Gravity

Sqrt = Square Root of

 

(b) KMLP may, from time to time, as operationally

necessary, establish and post on the Informational Postings portion

of its Interactive Website an upper limit on the dew point for

receipts on specified segments or other specified locations on its

system to prevent hydrocarbon fallout, or to assure that Gas will

be accepted for delivery into downstream entities. KMLP will

include in such posting the anticipated duration of the limitation.

KMLP will provide as much prior notice as reasonably practicable

and will attempt to provide in the posting at least ten (10)

Business Days prior notice before the limitation becomes effective.

If such prior notice is not practicable, KMLP will explain the

reason in the posting why it was unable to give such prior notice.

Upon request, KMLP will provide current information regarding the

dew point at any point of receipt into KMLP's System affected by

the posting to the operator of that point or any producer,

purchaser, supply aggregator or Shipper with Gas being tendered at

that point. KMLP shall not post, under this section, a

cricondentherm dew point temperature of less than fifteen degrees

Fahrenheit (15 degrees F).