19. QUALITY OF GAS

 

19.1 SPECIFICATIONS

 

(a) In order to permit delivery into downstream

facilities, the Gas received by KMLP under any Agreement shall meet

the following requirements, unless otherwise agreed:

 

(1) shall be free from objectionable liquids,

odors, solid matter, dust, gums, and gum forming constituents, or

any other substance which might interfere with the merchantability

of the Gas stream, or cause interference with proper operation of

the lines, meters, regulators, other appliances through which it

may flow, or transportation through any downstream pipeline;

 

(2) shall contain not more than seven (7) pounds

of water vapor per one thousand (1,000) MCF;

 

(3) shall contain not more than one quarter (1/4)

grain of hydrogen sulfide per one hundred (100) cubic feet of Gas;

 

(4) shall contain not more than five (5) grains of

total sulphur per one hundred (100) cubic feet of Gas, including

mercaptans and hydrogen sulfide;

 

(5) shall contain not more than four percent (4%)

by volume of nitrogen;

 

(6) shall contain not more than two percent (2%)

by volume of carbon dioxide;

 

(6.5) shall contain not more than four percent (4%)

by volume of total inerts;

 

(7) shall contain not more than ten parts per

million (10 ppm) by volume of combined oxygen;

 

(8) shall have a temperature of not more than one

hundred twenty degrees Fahrenheit (120 degrees F) and shall have a

minimum temperature of not less than forty degrees Fahrenheit (40

degrees F);

 

(9) the capacity of the System on which KMLP's

firm service obligation is predicated is based on receiving Gas

with a Btu content of at least 1065 Btu/cf. KMLP agrees to accept