Kinder Morgan Louisiana Pipeline LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 03/01/2009, Docket: RP09-257-000, Status: Effective
Original Sheet No. 222 Original Sheet No. 222
GENERAL TERMS AND CONDITIONS
----------------------------
outlined in the GPA Std 2145-00 Rev 1 Table of Physical Constants of
Paraffin Hydrocarbons and other Compounds of Natural Gas with any
subsequent amendments or revisions to such Report to which the
parties may mutually agree. Specific gravity shall be determined to
the nearest one thousandth (0.001).
17.5 SUPERCOMPRESSIBILITY
The measurement hereunder shall be corrected for deviation
from Boyle's Law at the pressures and temperatures under which Gas
is measured hereunder by the use of the AGA Report Nos. 3 and 9.
17.6 MEASURING EQUIPMENT
KMLP will install, maintain and operate or cause to be
installed, maintained and operated, measuring stations equipped with
flow meters and other necessary metering and measuring equipment by
which the volumes of Gas received and Equivalent Volumes delivered
hereunder shall be determined.
17.7 METERING
(a) Where measurement is by orifice meter, all
fundamental constants, observations, records and procedures involved
in the determination and/or verification of the quantity and other
characteristics of Gas delivered hereunder shall be in accordance
with the standards prescribed in the latest edition of A.G.A. Report
No. 3 (ANSI/API 2530) on "Orifice Metering of Natural Gas," with any
revisions, amendments or supplements as may be mutually acceptable
to KMLP and Shipper, unless otherwise specified herein.
(b) Where measurement is by turbine meter, unless
specified otherwise, shall be in accordance with A.G.A. Report No.
7, with any revisions, amendments or supplements as may be mutually
agreeable to the parties hereto.
(c) Where measurement is by ultrasonic meter, all
fundamental constants, observations, records and procedures involved
in the determination and/or verification of the quantity and other
characteristics of Gas delivered hereunder shall be in accordance
with the standards prescribed in the latest edition of A.G.A. Report
No. 9 on "Measurement of Gas by Multi Path Ultrasonic Meters" with
any revisions, amendments or supplements as may be mutually
acceptable to KMLP and Shipper, unless otherwise specified herein.