MidContinent Express Pipeline LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/10/2009, Docket: RP09-136-000, Status: Effective
Original Sheet No. 240 Original Sheet No. 240
GENERAL TERMS AND CONDITIONS
----------------------------
(9) shall have a combined composition of not
more than one and one-half (1.5) mole percentage of butane plus,
including isobutene, normal butane and all heavier hydrocarbons
(C4+);
(10) shall have a combined composition of total
inert gases (principally nitrogen and carbon dioxide) of not more
than four (4) mole percent; and
(11) shall have a Wobbe Index of not greater than
1400, calculated using Higher Heating Value (HHV), dry, based on the
following mathematical definition:
HHV / (Sqrt (SGgas) )
Where:
HHV = Higher Heating Value (Btu/scf)
SGgas = Specific Gravity
Sqrt = Square Root of
(b) MEP may, from time to time, as operationally
necessary, establish and post on the Informational Postings portion
of its Interactive Website an upper limit on the dew point for
receipts on specified segments or other specified locations on its
System (other than Leased Capacity) to prevent hydrocarbon fallout,
or to assure that Gas will be accepted for delivery into downstream
entities. MEP will include in such posting the anticipated duration
of the limitation. MEP will provide as much prior notice as
reasonably practicable and will attempt to provide in the posting at
least ten (10) Business Days prior notice before the limitation
becomes effective. If such prior notice is not practicable, MEP will
explain the reason in the posting why it was unable to give such
prior notice. Upon request, MEP will provide current information
regarding the dew point at any point of receipt into MEP's System
affected by the posting to the operator of that point or any
producer, purchaser, supply aggregator or Shipper with Gas being
tendered at that point. MEP shall not post, under this section, a
cricondentherm dew point temperature of less than fifteen degrees
Fahrenheit (15 degrees F).
(c) With respect to Leased Capacity, Gas received on
the Leased Capacity must meet the Gas quality standards established
by Enogex. MEP will post on its Interactive Website the Gas quality
standards in effect for the Leased Capacity.