White River Hub, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/01/2008, Docket: RP08-645-000, Status: Effective
Original Sheet No. 124 Original Sheet No. 124
GENERAL TERMS AND CONDITIONS
(Continued)
13.2 Cricondentherm Hydrocarbon Dew Point (CHDP).
(a) CHDP Limit - White River will accept all deliveries of
natural gas at a CHDP equal to or less than 15° Fahrenheit, provided that
such gas satisfies all other applicable provisions of White River's FERC Gas
Tariff.
(b) CHDP Operating Limit - White River may, from time to time,
as operationally feasible, establish and post on its internet web site a CHDP
Operating Limit that is higher than the CHDP Limit for natural gas received
into its system. White River's ability to establish and post higher CHDP
Operating Limits will depend on pipeline operating characteristics such as
pressures and temperatures, blending capability of prevailing and expected
gas supplies and proximity to interconnecting pipelines.
(c) White River shall not be obligated to accept gas into its
system that exceeds the applicable CHDP limit. The existence of a CHDP limit
shall not be deemed to negate, reduce or limit White River's authority to
issue operational flow orders. To the extent operationally practicable,
White River may waive a CHDP limit for gas received from certain points on
its system provided such waiver is made on a non-discriminatory basis.
13.3 CHDP Operating Limit Posting Procedure.
(a) White River may post a CHDP Operating Limit at or above the
CHDP Limit. The posted CHDP Operating Limit will apply to all receipt
points. White River will provide as much prior notice of changes to its CHDP
Operating Limits as possible and attempt to provide at least two days notice
prior to the timely cycle nomination deadline. However, White River may
reduce the CHDP Operating Limit to the CHDP Limit at any time without notice,
when operationally necessary. In such event, White River will post a
critical notice on its Internet web site.
(b) For receipt points with online chromatographs, White River
shall post on its internet web site the prior gas day average and maximum
calculated CHDP at each receipt point. For receipt points without online
chromatographs, once per month White River shall post on its internet web
site the average and maximum calculated CHDP at each receipt point for the
prior month period. Compliance with CHDP limits will be determined based on
calculated current flowing CHDP temperatures.