White River Hub, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/2008, Docket: RP08-645-000, Status: Effective

Original Sheet No. 123 Original Sheet No. 123

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

13. QUALITY OF GAS

 

13.1 The gas received by White River from Shipper and delivered by

White River to Shipper shall conform to the following specifications:

 

(a) Heat Content. The gas delivered at each of the points of

receipt and delivery shall contain a gross heating value of not less than 950

Btu per cubic foot nor more than 1150 Btu per cubic foot.

 

(b) Hydrogen Sulfide. The gas shall not contain more than 1/4

grain of hydrogen sulfide per 100 cubic feet.

 

(c) Inert Substances. The gas shall not contain inert

substances in excess of three percent by volume, of which carbon dioxide may

not exceed two percent by volume.

 

(d) Liquids. Gas tendered for transportation at a receipt point

shall not contain any free liquids of any nature and shall conform to the CHDP

specification set forth in §§ 13.2 and 13.3.

 

(e) Merchantability. The gas shall be commercially free from

dust, gums, gum-forming constituents, dirt, impurities or other solid or

liquid matter that might interfere with its merchantability or cause injury to

or interference with proper operation of the system, regulators, meters, or

other equipment of White River's. The gas shall also be free of all matter

that is deemed hazardous or toxic and is subject to regulation by the

Environmental Protection Agency or any State agency having similar

jurisdiction or authority.

 

(f) Oxygen. The gas shall not have an oxygen content in excess

of 10 parts per million by volume, and the parties shall make every reasonable

effort to keep the gas free of oxygen.

 

(g) Temperature. The gas shall be delivered at a temperature

not in excess of 120 degrees Fahrenheit at any receipt or delivery point.

 

(h) Total Sulfur. The gas shall not contain more than 0.75

grains of total sulfur per one hundred (100) cubic feet, of which not more

than 0.2 grains shall be mercaptan sulfur.

 

(i) Water Vapor. The gas shall not contain in excess of 5

pounds of water per million cubic feet.