Hardy Storage Company, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/01/2007, Docket: CP05-150-003, Status: Effective
Original Sheet No. 164 Original Sheet No. 164 : Effective
GENERAL TERMS AND CONDITIONS (Cont'd)
(l) Instrumentation and equipment to provide Records or samples
of gas necessary to determine the specific gravity, heating value, and/or
concentrations of nitrogen or carbon dioxide as required under Sections
26.6, 26.7 and 26.8 hereof may be installed at representative points along
the pipeline in lieu of installing such instrumentation and equipment at
each measuring station.
(m) Upon notice to Interconnecting Party, Seller may
prospectively implement and use any future editions or versions of the
American Gas Association or ANSI reports referenced in this Section 26.
26.10 Check Measuring Equipment.
(a) Interconnecting Party may install check measurement
equipment, provided such equipment does not interfere with the exercise of
Seller's rights to operate its station under this Tariff.
(b) Seller, in the presence of Interconnecting Party, shall
have access to Interconnecting Party's check measuring equipment at all
reasonable times, but the reading, calibration and adjustment thereof and
the change of charts shall be performed only by the Interconnecting Party,
unless otherwise agreed upon.
(c) Interconnecting Party shall exercise reasonable care in the
installation, maintenance and operation of its equipment so as to avoid any
inaccuracy in the determination of the quantity of gas delivered.
(d) The Records from such check measuring equipment shall
remain the property of the Interconnecting Party, but upon request the
Interconnecting Party will submit to Seller its Records and charts, together
with calculations therefrom, for inspection, subject to return within 30
days after receipt thereof.
26.11 Calibration and Testing of Meters. The accuracy of all measuring
equipment shall be verified by its operator at reasonable intervals and,
if requested, in the presence of representatives of the other party,
but neither Seller nor Interconnecting Party shall be required to perform a
special test to verify the accuracy of such equipment more frequently than
once in any 30-day period. If either party at any time desires a special
test of any measuring equipment, or if either party at any time observes an
error in any such measuring equipment, it will promptly notify the other
party, and the parties shall then cooperate to secure a prompt
verification of the accuracy of such equipment. The expense of any such
special test shall be borne by the requesting party if the measurement
equipment so tested is found not to be in error such that previous
Recordings from the equipment must be corrected under the provisions of
Section 26.12 herein.