Hardy Storage Company, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/01/2007, Docket: CP05-150-003, Status: Effective
Original Sheet No. 163 Original Sheet No. 163 : Effective
GENERAL TERMS AND CONDITIONS (Cont’d)
(e) The Records from measuring equipment shall
remain the property of the operator of such equipment, but upon request
the operator will submit to the other party its Records, together with
calculations therefrom, for inspection, subject to return within 30 days
after receipt thereof.
(f) Orifice meters shall be installed and operated, and gas
quantities computed, in accordance with AGA Report No. 3, American
National Standards Institute ANSI/API 2530, "Orifice Metering of Natural
Gas", revised Second Edition, 1985, applied in a practical and
appropriate manner, except that the supercompressibility factor shall be
calculated in accordance with Section 26.8 above.
(g) Turbine meters shall be installed and operated, and gas
quantities computed, in accordance with AGA Transmission Measurement
Committee Report No. 7, "Measurement of Gas by Turbine Meters", 1996
Edition, applied in a practical and appropriate manner, except that the
supercompressibility factor shall be calculated in accordance with
Section 26.8 above.
(h) Ultrasonic meters shall be installed and operated and gas
quantities computed in accordance with AGA Transmission Measurement
Committee Report No. 9, “Measurement of Gas by Multi Path Ultrasonic
Meters”, 1998 Edition, applied in a practical and appropriate manner,
except that the supercompressibility factor shall be calculated in
accordance with Section 26.8 above.
(i) Diaphragm meters shall be installed and operated, and gas
quantities computed, in accordance with ANSI B109.1 or B109.2, "Diaphragm
Type Gas Displacement Meters", 1986, applied in a practical and
appropriate manner, except that the supercompressibility factor shall be
calculated in accordance with Section 26.8 above.
(j) Rotary meters shall be installed and operated, and gas
quantities computed, in accordance with ANSI B109.3, "Rotary Type Gas
Displacement Meters", 1986, applied in a practical and appropriate
manner, except that the supercompressibility factor shall be calculated
in accordance with Section 26.8 above.
(k) Other types of meters may be used if mutually agreed to by
Seller and Customer.