Hardy Storage Company, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/01/2007, Docket: CP05-150-003, Status: Effective

Original Sheet No. 163 Original Sheet No. 163 : Effective

 

GENERAL TERMS AND CONDITIONS (Cont’d)

 

(e) The Records from measuring equipment shall

remain the property of the operator of such equipment, but upon request

the operator will submit to the other party its Records, together with

calculations therefrom, for inspection, subject to return within 30 days

after receipt thereof.

 

(f) Orifice meters shall be installed and operated, and gas

quantities computed, in accordance with AGA Report No. 3, American

National Standards Institute ANSI/API 2530, "Orifice Metering of Natural

Gas", revised Second Edition, 1985, applied in a practical and

appropriate manner, except that the supercompressibility factor shall be

calculated in accordance with Section 26.8 above.

 

(g) Turbine meters shall be installed and operated, and gas

quantities computed, in accordance with AGA Transmission Measurement

Committee Report No. 7, "Measurement of Gas by Turbine Meters", 1996

Edition, applied in a practical and appropriate manner, except that the

supercompressibility factor shall be calculated in accordance with

Section 26.8 above.

 

(h) Ultrasonic meters shall be installed and operated and gas

quantities computed in accordance with AGA Transmission Measurement

Committee Report No. 9, “Measurement of Gas by Multi Path Ultrasonic

Meters”, 1998 Edition, applied in a practical and appropriate manner,

except that the supercompressibility factor shall be calculated in

accordance with Section 26.8 above.

 

(i) Diaphragm meters shall be installed and operated, and gas

quantities computed, in accordance with ANSI B109.1 or B109.2, "Diaphragm

Type Gas Displacement Meters", 1986, applied in a practical and

appropriate manner, except that the supercompressibility factor shall be

calculated in accordance with Section 26.8 above.

 

(j) Rotary meters shall be installed and operated, and gas

quantities computed, in accordance with ANSI B109.3, "Rotary Type Gas

Displacement Meters", 1986, applied in a practical and appropriate

manner, except that the supercompressibility factor shall be calculated

in accordance with Section 26.8 above.

 

(k) Other types of meters may be used if mutually agreed to by

Seller and Customer.