Hardy Storage Company, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/01/2007, Docket: CP05-150-003, Status: Effective

Original Sheet No. 154 Original Sheet No. 154 : Effective

 

GENERAL TERMS AND CONDITIONS (Cont’d)

 

25.3 Heating Value. Seller shall not be required to accept natural

gas having a Heating Value of less than 967.

 

25.4 Objectionable Properties. The gas received and delivered:

 

(a) shall be commercially free from particulates or other solid

or liquid matter which might interfere with its merchantability or

cause injury to or interference with proper operation of the lines,

regulators, meters and other equipment of Seller;

 

(b) shall not contain more than twenty-five hundredths (0.25)

grains of hydrogen sulfide per one hundred (100) Cubic Feet of gas;

 

(c) shall not contain more than twenty (20) grains of total

sulfur per one hundred (100) Cubic Feet.