National Fuel Gas Supply Corporation

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/01/1997, Docket: RP97-201-000, Status: Effective

First Revsed Sheet No. 87 First Revsed Sheet No. 87 : Superseded

Superseding: 2nd Sub. Original Sheet No. 87

FSS RATE SCHEDULE

Firm Storage Service

 

 

2. APPLICABILITY AND CHARACTER OF SERVICE (Cont'd.)

 

2.3 Service hereunder shall consist of the receipt of natural gas

delivered to storage facilities utilized by Transporter pursuant to

Shipper's EFT, IT or FT Service Agreement, or pursuant to a

transportation agreement with another pipeline where operationally

feasible, the injection of gas into storage facilities utilized by

Transporter, the storage and withdrawal of that gas, and the

delivery of that gas, after reductions as set out in the FSS

Service Agreement and Section 3 of this FSS Rate Schedule, into

Transporter's transmission facilities for subsequent transportation

pursuant to Shipper's EFT, IT or FT Service Agreement, or pursuant

to a transportation agreement with another pipeline where opera-

tionally feasible Transporter shall not be required:

 

(a) to accept any gas during periods of time not within the Injec-

tion Period, as stated in the FSS Service Agreement,

 

(b) to accept on any day a quantity of gas in excess of the sum of

the Maximum Daily Injection Quantity (MDIQ) specified in the

FSS Service Agreement, and a quantity sufficient to satisfy

the retention described in Section 3.3 hereof,

 

(c) to accept on any day a quantity of gas at a point of intercon-

nection between storage facilities utilized by Transporter and

another pipeline in excess of the quantity of gas Transporter

is authorized and physically able to inject at such point of

interconnection, multiplied by a fraction, the numerator of

which is Shipper's Maximum Storage Quantity, and the denomina-

tor of which is the total top gas capacity in all of Trans-

porter's storage fields,

 

(d) to store a quantity of gas in excess of the Maximum Storage

Quantity (MSQ),

 

(e) to deliver any gas during periods of time not within the

Withdrawal Period, as stated in the FSS Service Agreement,