National Fuel Gas Supply Corporation
Fourth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/01/1997, Docket: RP97-398-000, Status: Effective
Original Sheet No. 340 Original Sheet No. 340 : Effective
GENERAL TERMS AND CONDITIONS
4. MEASURING EQUIPMENT (Cont'd.)
4.4 Installation
All installations of measuring equipment, applying to or
affecting receipts or deliveries by Transporter, shall be made in
such manner as to permit an accurate determination of the
quantity of gas delivered and ready verification of the accuracy
of measurement. Reasonable care shall be exercised in the
installation, maintenance and operation of any pressure
regulating equipment so as to avoid, as far as practicable, any
inaccuracy in the determination of the volume of gas delivered
hereunder.
4.5 Access to Meters and Records
Transporter and Shipper or Operator shall have the right to be
present at the time of any installing, reading, cleaning,
changing, repairing, inspecting, testing, calibrating, or
adjusting done in connection with the other's equipment used in
measuring or checking receipts and deliveries of gas. The
records from such equipment shall remain the property of their
owner, but upon request, each will submit to the other its
records and/or charts, together with calculations therefrom, for
inspection and verification, subject to return within ten (10)
days after receipt thereof.
4.6 Measurement Equipment Failures
In the event measurement equipment is out of service, or
registering inaccurately, the quantity and/or volume of gas
received or delivered by Transporter shall be estimated:
(a) By using the registration of any check meter, meters or
other measurement equipment if installed and accurately
registering, or in the absence of "(a)";
(b) By correcting the error if the percentage of error is ascer-
tainable by calibration, test or mathematical calculation
or, in the absence of both "(a)" and "(b)", then;
(c) By estimating the quantity of receipt or delivery by
reference to receipts or deliveries during periods under
similar conditions when the meter was registering
accurately.