Texas Eastern Transmission, L P
Seventh Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/16/2009, Docket: RP10-53-000, Status: Effective
Third Revised Sheet No. 390 Third Revised Sheet No. 390
Superseding: Second Revised Sheet No. 390
RATE SCHEDULE FSS-1
(Continued)
5.2 Pipeline shall permit transfers of title of Gas in Storage Inventory, provided both
Customers have executed a service agreement under Rate Schedules SS-1, FSS-1 and/or
ISS-1 and that such transfer does not permit either Customer to exceed its MSQ
specified in such service agreement. Such transferred quantities shall not be included
in any Customer's Storage Inventory for purposes of determining Customer's daily
withdrawal rights pursuant to Section 6 until twenty-four (24) hours following the date
of transfer or as provided in Section 6.3 of this Rate Schedule. In lieu of
transferring its Storage Inventory to another storage service Customer, Customer may
transfer all or a portion of its Storage Inventory to another of its Open-Access
storage service agreements, provided that no portion of the term of the agreements
involved in the transfer overlap. A Customer that desires to transfer Storage
Inventory to another Customer or to another of its Open-Access storage service
agreements must submit the required information, which shall include, at a minimum, the
identification of the storage service agreements involved in the transfer, the quantity
to be transferred, and the effective date of the transfer, via the LINK® System. If a
proposed transfer involves a storage service agreement that has terminated, the
required information must be submitted within three (3) Business Days after the end of
the term of the applicable agreement. The proposed transfer must be confirmed via the
LINK® System by the Customer to whom the Storage Inventory is to be transferred before
the transfer is processed by Pipeline.
5.3 In addition to accepting Gas for storage injection at the FSS-1 Storage Point, Pipeline
will accept Gas tendered at points of interconnection between Pipeline and third party
facilities at Oakford and Leidy Storage Fields provided that such receipt does not
result in Customer tendering aggregate quantities for storage in excess of the Customer
MDIQ.
5.4 Notice Required. The notice given by Customer to Pipeline for injections on any Day
shall be in accordance with Section 4 of Pipeline's General Terms and Conditions of
this FERC Gas Tariff.
5.5 Injection Quantities. The maximum injection Quantity of Gas which Pipeline is
obligated on any Day to inject into storage under this Rate Schedule shall be the MDIQ.
5.6 Limitation Upon Total Injections. Pipeline shall be obligated to accept Gas for
storage for Customer's account in accordance with the above procedure only when
Customer's Storage Inventory is less than Customer's MSQ.